50
TIP & TEMPERATURE SELECTION
With any heating system, actual tip temperatures can differ greatly from temperature control settings.
PACE’s unique “Tip & Temperature Selection System” allows you to select and maintain True Tip
Temperatures for any size and type of tip and handpiece using the appropriate TIP OFFSET CONSTANT.
Included with your system is a Chart Holder which holds Procedural Instructions, a Quick Reference
Guide, a Customer Log and Charts for each handpiece currently available from PACE. Follow the
procedure given in the chart marked “Introduction” when using the charts for any particular handpiece.
Listed below is the summarized procedure.
PROCEDURE
Select the appropriate Handpiece Chart for your application based on component type and/or procedure
(e.g., SMD removal, thru-hole soldering, etc.) and identify the correct tip. Install tip into handpiece and
follow the procedure below.
1. In
Tip Temperature Offset
(
TIP OFFSET
) Mode, enter the TIP OFFSET CONSTANT (# in
shaded area) corresponding to your selected tip for the channel powering the handpiece.
2. In
Tip Temperature Set
(
TIP SET
) Mode, set
ANY
desired Tip Temperature up to the
maximum. The tip will idle at this temperature.
NOTE
The Tip Offset Value is internally calculated and adjusted automatically
(based on the TIP OFFSET CONSTANT) so that a True Tip Temperature is
always displayed on the Digital Readout - even when the desired Set Tip
Temperature is changed.
Summary of Contents for PRC 2000
Page 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Page 2: ...2 ...
Page 3: ...3 MANUAL NO 5050 0313 REV G ...
Page 17: ...17 Figure 6 Thermal Management Center ...
Page 23: ...23 Figure 12 Pik And Paste Section ...
Page 74: ...74 ...
Page 95: ...95 Figure 122 Pulse Plate Set Up ...
Page 96: ...96 ...
Page 102: ...102 ...
Page 111: ...111 ...
Page 119: ...119 ...