9
Storage Temperature:
-40°C to 100°C (-40°F to 212°F).
THERMAL MANAGEMENT CENTER
VACUUM AND AIR
Measurements at front panel
SNAP-VAC
and Controllable
PRESSURE
Ports of power source.
Vacuum Rise Time:
Evacuates 33 cc (2 cubic inches) volume
to 25 cm Hg. (10 in. Hg.) in 150 ms.
Vacuum:
51 cm Hg. (20 in. Hg.) (nominal)
Pressure:
.
48 Bar (7 P.S.I.) (nominal
MAX
setting)
Air Flow:
13 SLPM (0.46 SCFM) maximum.
TEMPERATURE SPECIFICATIONS
Tip Temperature Range:
38°C to 482°C (100°F - 900°F) (see note).
Digital Readout Resolution:
± 1° (°C or °F)
Tip Temperature Stability:
± 1.1 °C (2°F) at idle from Set Tip Temperature.
NOTE
True minimum and maximum Operating Tip Temperatures may vary
depending on handpiece & tip selection.
EOS/ESD
Tip-To-Ground
Resistance:
Less than 5 ohms.
AC Leakage:
Less than 2 millivolts RMS from 50Hz to 500Hz, min.