Handpiece Vacuum/Pressure
NOTE:
The Air Hose and Slide Rod must be positioned to prevent any kinking of the hose. Kinks in
the hose will prevent proper airflow when the system is operated and will cause a
deterioration in performance.
Corrective Maintenance
Listed below are message codes which may be displayed on the Digital Readout if a mistake is made by
the operator (e.g., wrong password entry) or if the system has malfunctioned.
Display Error Message
Description
Wrong Password
The incorrect Password has been entered. The
displayed message will time out after 3 seconds and
revert to normal operation. Enter the correct
Password.
Open Sensor
The heater assembly sensor is open.
Replace heater assembly.
Blower Run Error
The power source blower unit is not running. Contact
PACE for assistance.
Power Source/Handpiece
Refer to the table below. Most malfunctions are simple and easy to correct.
Symptom
Probable Cause
Solution
Blown Fuse
Inspect and replace the fuse(s) located on the
power source rear panel.
No power to system
Line cord
unplugged
Plug line cord into the appropriate AC outlet.
Heater Assembly does
not heat. No
malfunction indicated
on Digital Readout.
Open Heater
Contact PACE for assistance.
Little or no air flow,
heater heats and
blower is running
Kinked air hose
Change routing of air hose to remove
kinks.
Display on Digital
Readout indicates a
malfunction.
Refer to Display Error Messages.
Little or no vacuum
Worn vacuum
pump
Replace vacuum pump. Contact PACE for
assistance.
Vacuum Cup will not
hold component
Worn or broken
vacuum cup
Replace vacuum cup.
Vacuum Pickup Rod
binding
Vacuum Pickup
rod is bent
Refer to the Vacuum Pick Replacement manual.