11
CAUTION
Systems connected together through the PaceLink must be used and controlled
by a single operator. Any attempt to operate by more than one individual can
create a hazard condition and will cause a deterioration in performance.
Ensure that only one air hose is connected to the AUTO SNAP-VAC or
Controllable PRESSURE port at one time. Attachment to both ports
simultaneously will cause a deterioration in performance.
PACELINK
The PaceLink Receptacle on the front panel of the power source allows the you to
link your ST 40A system to the AUTO SNAP-VAC and Controllable PRESSURE
features of a ST 60 system . If an air handpiece (SX-70, TP-65 or TJ-70) is
connected to the ST 40A, actuation of its finger switch will activate air flow
through the AUTO SNAP-VAC and Controllable PRESSURE ports of the ST 60
system. To link your ST 40A system to a ST 60 system, perform the following
procedure.
1. Place your ST 40A & ST 60 systems
adjacent to each other (side by side
or stacked one on top of the other).
2. Use a PaceLink cable (available from
your local PACE distributor)) to
connect the systems. Place the plugs
ends of the cable into the PaceLink
Receptacles on both systems.
3. Ensure that a VisiFilter assembly is
connected to the ST 60 AUTO
SNAP-VAC Port.
4. Connect the Air Hose of the
handpiece currently in use to the
VisiFilter assembly or Controllable
PRESSURE Port.