SX-70
6
Handpiece Setup
NOTE
If using your SX-70 handpiece for the first time or if you have just replaced the
heater, we recommend that you follow the “SX-70 Heater Burn-in” procedure
(Red tag on handpiece) to increase the life expectancy of the heater.
Handpiece Connection
Connect the handpiece connector plug into one of the Power Receptacles on your
PACE power source in the following manner.
1. Align guide on connector with slot on power
receptacle.
2. Insert connector into power receptacle.
3. Turn the connector housing clockwise to
lock in place.
Air Hose Connection
NOTE
Ensure that only one air handpiece is connected to either the
Vacuum
Port
or Controllable
PRESSURE
Port at one time. Attachment to both
ports simultaneously will cause a deterioration of performance.
To set up your SX-70 air hose connection, perform the following steps:
1. Air Hose To Handpiece Connection
a) Attach one end of a 137cm (54 inch) length of air hose to the metal
tube in the back of the handpiece.
b) If you have a PACE system incorporating only one handpiece, attach
the air hose to the SX-70 power cable using the supplied Hose
Clamps. Space them evenly along the length of the power cable
starting at a point 6 inches from the ends of the handpiece.
c) If you have a PACE system incorporating 2 or more air handpieces
(e.g., SX-70, DTP-80, TJ-70, TP-65), you may wish to leave the air
hose assembly unattached to allow a quick change to any air
handpiece being used.