Default Factory Settings
The WJS-100 system comes equipped with a number of features, which may be adjusted by the user.
Listed below are the features and default settings of each. To change and/or learn about any of
these features, refer to the applicable part of the “Customizing Your System” section of this manual.
Available Tips – ONLY USE 1128 SERIES TIPS with GOLD END CONNECTORS
1128-0001-P1 TWJS High Performance TIP, 1/32" Conical Sharp Extended
1128-0002-P1 WJS High Performance TIP 1/64" Conical Sharp
1128-0003-P1 WJS High Performance TIP 1/64" Conical, Sharp, Bent 30 Degree
1128-0008-P1 WJS High Performance TIP 3/64" 30 Degree Chisel
1128-0010-P1 WJS High Performance TIP 13/64" Chisel
1128-0012-P1 WJS High Performance TIP 1/32" 30 Degree Chisel
1128-0013-P1 WJS High Performance TIP 3/32" 30 Degree Chisel
1128-0019-P1 WJS High Performance TIP 1/16" 30 Degree Chisel
1128-0032-P1 WJS
High
Performance TIP MINIWAVE
1128-0037-P1 WJS High Performance TIP 0.25" Knife Blade
System Calibration
All systems are tested for temperature accuracy at the factory and can be checked for
calibration according to requirements. No internal adjustments can be made to the power
supply.
To Adjust Digital Temperature Control Systems
1. After the system/tip has stabilized, measure the tip temperature with whatever method
you use.
2. Turn off power source and turn it back on while holding down the program (round) key
and the up key.
3. The system will prompt you to enter the measured temperature using the keypad.
4. Press the program key and the system will restart.
5. To clear the calibration, remove the handpiece while the power source is ON.
Feature Factory
Setting
Password None
Entered
°F for 115 VAC Systems
Default Temperature Scale (°C/°F)
°C for 230 VAC Systems
“HI” (Upper) Temperature Limit
454 °C (850 °F)
“LO” (Lower) Temperature Limit
204 °C (400 °F)
Set Temperature
“OFF”
Tip Offset Constant
“0”
Temperature Setback
Enabled, 30 minutes
Auto Off
Enabled, 30 minutes