Page 4 of 8
TA v.12.2015
Domestic Hot Water storage tanks
T
T
T
A
A
A
Cathodic protection using impressed current electronic anode (standard)
As an alternative to galvanic systems (combination of materials with different electrical potential) another protection method is available, consisting in
imparting to the metal structure to be protected a direct current equal and opposite, obtaining this way the neutralization of voltages formed inside the
tank.
Thanks to modern techniques, an innovative cathodic protection electronic system is available, by impressing direct current.
Main advantages are:
active protection by impressing direct current from an external source
excellent operational flexibility, for respond to different types of internal lining and to variable mass of water
maintenance costs reduction due to the permanent protection of the system
Thermal insulations
HARD POLYURETHANE FOAM
Hard foam polyurethane injected
Insulation made of hard polyurethane 55mm thick with closed cells content higher than 93%. It’s injected directly on the tan
k enclosed inside a cylinder
mould. I
t’s self
-extinguishing according to ISO 3582 (class B2, DIN 4102), density of 40÷42 kg/m3, average conductivity of 0,019 W/mK at 45°C. CFC and
HCFC free.
Removable hard foam polyurethane semi-shells
Insulation made of hard polyurethane 55mm thick with clos
ed cells content higher than 93%. It’s composed of two removable semi
-
shells. It’s self
-
extinguishing according to ISO 3582 (class B2, DIN 4102), density of 40÷42 kg/m3, average conductivity of 0,019 W/mK at 45°C. CFC and HCFC free.
Thickness
Density
Thermal conductivity coefficient
at 45°C
55mm
40÷42 kg/m3
= 0,019 W/mK
PLF
–
POLYESTHER FIBER
Polyesther fiber
Insulation made of soft polyesther fiber 50mm foam, density of 20 kg/m3, average conductivity of 0,037 W/mK at 45°C. CFC and HCFC free. According to
DPR 412/93, implementation of Italian Law 10/91.
Thickness
Density
Thermal conductivity coefficient
at 45°C
50mm
20 kg/m3
= 0,037 W/mK
External finishing is made of coloured PVC cover with zipper closing.
Compliance
“Pacetti” hot water
cylinders for storage and production of Domestic Hot Water of for heating systems are made with automatic welding processes,
using DD11 pickled carbon steels or 316L stainless steel.
All manufacturing processes are guaranteed by the Quality Management System of the Company, certified to ISO 9001:2008.
The products, in all versions, are subjected to hydraulic tests at a pressure equal to 1.5 times the maximum working pressure.
All “Pacetti” products are designed, manufactured and tested according to an accur
ate engineering practice (Law 46 of 05/03/1990
–
material
constructed in a workmanlike manner) and comply with the following standards:
-
European Pressure Equipment Directive 97/23/CE
–
Par.3.3
(pressure vessels) for which the tanks enclosed in this catalogue must be considered
exempt from CE mark.
-
Ecodesign requirements for energy-related products
–
Directive 2009/125/EC
-
D.M. 174/04 or EC 1935/04 Regulation
(on materials intended for food contact)
-
D.P.R. 412/93
implementation of Italian Law 10/91
Cooke Industries - Phone: +64 9 579 2185 Fax: +64 9 579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz