Domestic Hot Water storage tanks

 

 

 

 

 

 

T

T

T

A

A

A

 

 

 

1.

 

WARNINGS 

This instruction manual is an essential part of the product and must be given to the final user. 
Carefully read the suggestions contained in this manual, as they provide important information about installation, use and maintenance of the product. 
Keep this manual for future reference. 
The installation must be made in accordance with current regulations, according to the manufacturer's instructions and must be carried out by qualified 
personnel only,  in order to keep warranty valid. 
A wrong installation can cause damages to people, animals and things.  
The manufacturer will not be responsible for any damage caused by a wrong installation.  
This cylinder is designed to store domestic hot water, therefore it must be connected to the heating system, the water mains and the domestic hot water 
distribution network. 
The use of the product for purposes other than those specified in this manual is forbidden. 
The manufacturer will not be responsible for any damage caused by misuse, incorrect or unreasonable use. 
The packaging must be disposed according to local regulations. 
To clean the exterior of the cylinder, use a cloth dampened with a proper cleaner. 
The use of abrasive or solvents is not recommended. 
Disconnect the unit from any power source before carrying out any assistance or maintenance operation. 
In case of malfunction should shut off the unit and ask for the intervention of the installer. 

 
2.

 

INSTALLATION 

THIS OPERATION MUST BE MADE SOLELY BY QUALIFIED PERSONNEL, PENALTY THE LOSS OF WARRANTY. 

2.1.

 

FIRST CHECK 

This cylinder has been designed, manufactured and tested for the storage of domestic hot water within the limits of temperature and pressure indicated 
in the chapter "technical data" and on the id label applied on the product itself. Any use beyond the allowed limits should be considered dangerous and 
not suitable. 

 

2.2.

 

PLACEMENT 

 

install the cylinder sheltered from the weather 

 

install the cylinder as close as possible to the primary heat source 

 

install the cylinder on a flat surface of suitable strength, able to support the weight of the product once filled with water 

 

check that there is enough space around the tank in order to perform future maintenance 

 

verify that the room where the tank is located has openings of a size to allow the free passage of the cylinder, in case it's necessary to bring it 
out, in order to avoid any demolition. 

2.3.

 

START 

 

The connection diagram shown in this document is purely indicative and not binding. it's up to the designer of the system to choose the best 
connection scheme for the required application, in accordance either with the applicable regulations and with the limits imposed by the data 
declared by the manufacturer. 

 

The connection to the water mains must be done through a safety hydraulic kit including: 
- 1 shut-off valve 
- 1 check valve 
- 1 safety valve 
- 1 stop device of water supply 
all the above accessories are necessary to make the tank installation safe from dangers 

 

provide  the  system  of  an  expansion  vessel  including  a  relief  valve  (of  counterweight  or  spring  type)  having  a  diameter  not  less  than 

  where V is the volume in litres of the cylinder, with a minimum of  15mm. The valve must be set at a pressure not exceeding 

the maximum working pressure of the tank 

 

make sure that the volume and the pre-charge pressure of the expansion vessel of the secondary circuit are suitable for the installation 

 

if the sanitary water system exceeds the maximum pressure allowed for the cylinder, install a pressure reducer as far away as possible from 

the storage tank 

 

in case the calcium value of the water coming from mains is too high, install a properly sized softener (before the storage tank) 

 

in case impurities are contained in the water coming from mains, install a suitable filter 

 

make sure that the pumps have enough flow and head and work correctly 

 

make sure that the thermometer and thermostat probes are positioned correctly 

 

always perform the grounding of the tank 

 

in case the users are many, located far from the unit, and require discontinuous supply of water, the installation of a recirculation pump is 

suggested, in order to keep constant the temperature of the domestic hot water. This way it's possible to avoid long waits and waste of cold 
water 

 

the insulation of the connecting pipes is always recommended in order to avoid unnecessary heat loss 

Cooke Industries - Phone: +64 9 579 2185  Fax: +64 9 579 2181  Email: sales@cookeindustries.co.nz  Web: www.cookeindustries.co.nz

Summary of Contents for TA-S

Page 1: ... of 8 TA v 12 2015 T T TA A A Domestic hot water storage tank USER AND MAINTENANCE MANUAL Cooke Industries Phone 64 9 579 2185 Fax 64 9 579 2181 Email sales cookeindustries co nz Web www cookeindustries co nz ...

Page 2: ...orizontal version Enamelled steel cylinders TA S TA C Capacity Dimensions 5 D d H L H1 Litre mm mm mm mm mm 200 550 450 1510 1410 720 300 650 550 1550 1460 820 500 750 650 1840 1760 920 800 900 800 1910 1840 1060 1000 900 800 2160 2090 1060 1500 1050 950 2470 2360 1220 2000 1200 1100 2530 2430 1360 2500 1300 1200 2600 2500 1510 3000 1350 1250 2800 2700 1550 4000 1500 1400 2880 2800 1700 5000 1700 ...

Page 3: ...moisture absorption and the thermal stability is maintained at both high and low temperatures so that excursions from 5 C to 95 C are well supported by this enamel even with frequent cycles of maximum stress High impact resistance and very low friction coefficient allow to prevent dangerous phenomena of adhesions which are due for the most cases to calcareous deposits Low dielectric constant which...

Page 4: ...of 40 42 kg m3 average conductivity of 0 019 W mK at 45 C CFC and HCFC free Thickness Density Thermal conductivity coefficient at 45 C 55mm 40 42 kg m3 0 019 W mK PLF POLYESTHER FIBER Polyesther fiber Insulation made of soft polyesther fiber 50mm foam density of 20 kg m3 average conductivity of 0 037 W mK at 45 C CFC and HCFC free According to DPR 412 93 implementation of Italian Law 10 91 Thickne...

Page 5: ...ith water check that there is enough space around the tank in order to perform future maintenance verify that the room where the tank is located has openings of a size to allow the free passage of the cylinder in case it s necessary to bring it out in order to avoid any demolition 2 3 START The connection diagram shown in this document is purely indicative and not binding it s up to the designer o...

Page 6: ...ere s no water loss ELECTRONIC ANODE This device is not subject to wear It must be connected to the main power from which it absorbs only 3 W The titanium anode immersed in the tank is electrically feed by the device but is not consumed Be sure the power is correctly and constantly connected Short power interruptions are not dangerous and don t cause any damage Long power interruptions days or wee...

Page 7: ...reated as household waste the metallic components should be sold to operators authorized to the collection of materials for recycling the non metallic components should be transferred to operators authorized to their disposal Cooke Industries Phone 64 9 579 2185 Fax 64 9 579 2181 Email sales cookeindustries co nz Web www cookeindustries co nz ...

Page 8: ...r l Via Marconi 240 242 44122 FERRARA Tel 39 0532 774066 Fax 39 0532 773835 e mail info pacetti it web www pacetti it Cooke Industries Phone 64 9 579 2185 Fax 64 9 579 2181 Email sales cookeindustries co nz Web www cookeindustries co nz ...

Reviews: