background image

AeGIS8000P 

Page 29 

 

 

Summary of Contents for AeGIS 8000 PLUS

Page 1: ...INSTALLATION AND PROGRAMMING MANUAL Rev 02 2011...

Page 2: ...BLE OF CONTENTS Chapter 1 GETTING STARTED 4 Chapter 2 INSTALLATION WIRING DIAGRAM 11 Chapter 3 PROGRAMMING 13 Chapter 4 SYSTEM S OPERATION 24 Chapter 5 TROUBLE SHOOTING GUIDE 26 GENERAL FCC REQUIREMEN...

Page 3: ...the information herein implied Pach and Company does not assume any liability for any damages which may arise in installation or use of the AeGIS 8000P Series Pach and Company does not assume liabili...

Page 4: ...code which is entered on the system keypad The tenants MUST have a telephone to allow remote visitor access Also as a standard feature the tenant is allowed to call the Aegis unit and converse with th...

Page 5: ...ow 32 F o Relay Output Form C Dry Contact 120 VAC 10A 24VDC 10A 250VAC 7A o Memory Type Non volatile o Tone Detection Crystal controlled capable of detecting short bursts 80 ms o Ringer Equivalence 0...

Page 6: ...ts are warranted to be free of defects in material or workmanship for a period of 24 month from the date of purchase This warranty extends only to wholesale customers who buy direct from Pach and Comp...

Page 7: ...ce accidents or Natural disasters o Warranty is immediately null and void if the product has been altered repaired or modified without express written authorization from Pach and Company Technical Dep...

Page 8: ...RMA numbers will not be issued to the end user consumers Consumers must contact their selling dealer installer for any all warranty issues o Distributor and or Dealer Installer are responsible for al...

Page 9: ...sible for time travel and or labor costs of any distributor and or dealer installer including but not limited to any expenses to install uninstall or reinstall hardware software firmware related to wa...

Page 10: ...ges incl freight and insurance fees for products shipped to Pach and Company repair center o Pach and Company warranty does not guarantee any product new or repaired to be free of operation error or s...

Page 11: ...and 3 Clear the memory 4 Adjust the speaker volume press wait for dial tone clockwise decrease counter clockwise increase refer to figure 2 1 5 Adjust the display intensity refer to figure 2 1 LCD DIS...

Page 12: ...e memory 4 Adjust the speaker volume press wait for dial tone clockwise decrease counter clockwise increase refer to figure 2 1 Adjust the display intensity refer to figure 2 1 p11 LCD DISPLAY OK FLAS...

Page 13: ...git Master Code 0000 is default master code 2 The screen will show as below if the master code is valid Long beep if the master code is invalid need key to unlock the system then use the second method...

Page 14: ...tion code 00 then press 2 Enter new 4 digit master code then press 01 ADDING NEW TENANT DIRECTORY Each tenant must have unique directory Directory can be set 2 4 digit See function code 06 p17 Must be...

Page 15: ...ayout page 14 Press after entering last letter The screen will show 4 Enter telephone number up to 11 digit then press 5 Enter 4 digit access code then press Enter the Name _ _ _ _ _ _ _ _ _ _ _ _ _ P...

Page 16: ...1 98 hours timer 99 open for indefinite time Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 05 then press 2 Enter 01 98 hours timer 00 close or...

Page 17: ...p to 48 characters and divided into 3 segments and 16 characters for each segment Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 10 then press...

Page 18: ...13 1 Enter function code 14 then press 2 Enter the hour in military then press Enter the minute then press 15 DAY LIGHT SAVING 0 live in no day light saving zone 1 live in day light saving zone Must...

Page 19: ...then press 2 Enter 1 9 default is 9 then press 21 REMOTE OPEN DOOR 2 DTMF NUMBER Select 1 9 Default is 8 Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter func...

Page 20: ...V22 Default is V22 Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 70 then press 2 Press 1 V22 or 0 BELL then press 71 ENABLE MODEM 0 Disable 1...

Page 21: ...page 13 1 Enter function code 74 then press 2 Press 1 enable or 0 disable then press 75 KEYPAD BEEP OFF 1 enable beep on 0 disable beep off Default is 1 enable Must be in programming mode see Two way...

Page 22: ...phabetical order Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 78 then press the display will show as an example shown 2 Press 3 scroll A Z 6...

Page 23: ...Number of tenants are occupied the system memory Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 91 then press 2 The display above is shown the...

Page 24: ...lished a communication 2 Press the voice mail or extension number using the system s keypad E How to extend talk time Talk time is set using function code 79 10 180 seconds see p22 1 Establish a commu...

Page 25: ...2 Turn counter clockwise to increase or clockwise to decrease I How to increase or decrease the speaker s volume 1 Locate the speaker s volume adjustment see figure 2 1 p11 2 Turn counter clockwise t...

Page 26: ...off and on 2 Check the speaker and microphone connection check for broken wires 3 Disconnect the microphone and speaker connector then check the speaker s impedance must read between 18 24 ohms DISPLA...

Page 27: ...DSL filter Hear radio station on phone line 1 Ground or remove the ground 2 Power the board outside the cabinet 3 Install a DSL filter 4 Install RF filter DOOR OR GATE PROBLEMS Remote access 9 does n...