background image

14

ALT5.CPINSB  080515-24

©PACIFIC ENERGY FIREPLACE 
PRODUCTS LTD.

Operation

Wood Selection

This heater is designed to burn natural wood only.  Higher 
efficiency and lower emissions generally result when burning 
air-dried seasoned hardwoods, as compared to softwoods or 
too green or freshly cut hardwoods.
Wood should be properly air dried (seasoned) for six months 
or more.  Wet or undried wood will cause the fi re to smoulder 
and produce large amounts of creosote.  Wet wood also pro-
duces very little heat and tends to go out often.

DO NOT BURN :

 

 

-Salt water wood  * 

 

-Treated wood

 

 

-Wet or green wood   

 

-Coal/charcoal

 

 

-Garbage* 

  -Solvents

 -Lawn 

clippings/yard 

waste -Unseasoned 

wood

 

-Railroad ties 

 

-Manure or animal remains

 

-Materials containing rubber, including tires

 

-Materials containing plastic

 

-Waste petroleum products, paints or paint 

 

thinners, or asphalt products

 

-Materials containing asbestos

 

-Construction or demolition debris

 

-Paper products, cardboard, plywood, or particleboard.

*  These materials contain chlorides which will rapidly 
destroy metal surfaces and void warranty.

Burning these materials may result in the release of toxic fumes 
or render the heater ineffective and cause smoke.

The prohibition against burning these materials does not pro-
hibit the use of fi re starters made from paper, cardboard, saw 
dust, wax and similar substances for the purpose of starting 
a fi re in an affected wood heater.
Do not burn anything but wood.  Other fuel, e.g. charcoal, 
can produce large amounts of carbon monoxide, a tasteless, 
odourless gas that can kill.  Under no circumstances should 
you attempt to barbecue in this heater.

How to Test Your Wood

Add a large piece of wood to the stove when it has a good, 
large bed of coals.  It is dry if it is burning on more than one 
side within one minute.  It is damp if it turns black and lights 
within three minutes.  If it sizzles, hisses and blackens without 
igniting in fi ve minutes it is soaked and should not be burnt.

WARNING:  Do not use grates or andirons to elevate the 
fuel.  Burn directly on the fi rebricks.  Replace broken or 
missing bricks.  Failure to do so may create a hazardous 
condition.

Your Pacifi c Energy heater is designed for maximum overall 
efficiency at a moderate fi ring rate.  Overfi ring is hazardous 
and a waste of fuel.  Too slow a burn contributes to creosote 
buildup and lowers combustion efficiency.

Lighting a Fire

WARNING: Never use chemicals or any other volatile 
liquid to start a fi re.

1.  Adjust air control to “High” position(all the way to the left) 

and open door.

2.  Place crumpled newspaper in the centre of the heater and 

criss-cross with several pieces of dry kindling.  Add a few 
small pieces of dry wood on top.

3.  Ignite the paper and leave the door ajar approimately 

1/2”(13mm) - 1”(25mm) until the wood kindling is fully 
engulfed in fl ame.

4.  After the kindling is fully engulfed add a few small logs.  

Close door.

5.  Begin normal operation after a good coal base exists and 

wood has charred.

Curing of the Paint Finish

When burning your stove for the fi rst 2-3 times it is very im-
portant that the room be well ventilated.  Open all windows 
and doors.  Smoke and fumes caused by the curing process 
may cause discomfort to some individuals.

Normal Operation

WARNING:  This wood heater has a manufacturer-set mini-
mum low burn rate that must not be altered. It is against 
federal regulations to alter this setting or otherwise oper-
ate this wood heater in a manner inconsistent with the 
operating instructions in this manual.

1)  Set air control to desired setting.  If smoke pours down 

across the glass (waterfall effect), this indicates you have 
shut the control down too soon or you are using too low a 
setting.  As every home’s heating needs vary (i.e. insula-
tion, windows, climate, etc.), the proper setting can only 
be found by trial and error and should be noted for future 
burns.

2)  To refuel, adjust air control to "H" (high) position (pushed 

to the far left) and give the fi re time to brighten.  Open door 
slowly, this will prevent backpuffing.

3)  Use wood of different shape, diameter and length (up to 

19").  Load your wood endwise and try to place the logs 
so that air can fl ow between them.  Always use dry wood.

4)  Do not load fuel to a height or in such a manner that would 

be hazardous when opening the door.

5)  For extended or overnight burns, unsplit logs are preferred.  

Remember to char the wood completely on "H" (high) set-
ting before adjusting air control for overnight burn.

WARNING:  Always keep loading door closed when burn-
ing.  If the door is left partly open, gas and fl ames may 
be drawn out of the fi replace  stove  opening creating 
risks from fi re and/ or smoke. This heater is not designed 
for open door burning, unless a manufacturer supplied 
screen is used. 

Summary of Contents for Alderlea T5 Classic Insert

Page 1: ...ED and LISTED to ULC S628 UL 1482 Meets the U S Environmental Protection Agency s May 2015 Particulate Emission Standards SERIAL SAFETY NOTICE If this stove is not properly installed a house fire may...

Page 2: ...1 Warranty Information 22 Label 23 PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of theAlderlea T5 INSERT wood heater This heater meets the 2015 U S Environmental...

Page 3: ...t restrictions and installation inspection require ments in your area Clearances Masonry or Factory Built Fireplace Theminimumrequiredclearancestosurroundingcombustible materialswheninstalledintoamaso...

Page 4: ...Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping...

Page 5: ...ace opening may be flush to an adjacent combustible floor Ember protection Combustible floor in front of the fireplace insert must be protected from hot embers by non combustible material extend ing 1...

Page 6: ...IFIC ENERGY FIREPLACE PRODUCTS LTD 29 3 8 42 1 2 30 3 8 42 1 2 33 1 8 34 1 8 9 1 2 33 5 8 23 7 8 10 5 8 17 5 8 20 7 8 17 5 8 28 3 8 21 1 2 WITH REGULAR SURROUND WITH OVERSIZED SURROUND ALT5 INSERT ALT...

Page 7: ...in use for some time have chimney swept The existing fireplace damper is to be locked open or removed completely WARNING Do not remove bricks or mortar from your existing fireplace Exception Masonry...

Page 8: ...r area and into the first chimney flue tile Seal around pipe Note A clean out door may be required under local codes whenadirectflueconnectionisused Consultlocalcodes 3 To mount optional rear leveling...

Page 9: ...tion When the installation is complete do not seal surround to fireplace This will allow enough combustion air to enter the fireplace cavity and the Insert The knockouts in the casing sides and the O...

Page 10: ...Fig 10 Use the bolts and washers in the mounting hardware kit found with the Surround Top Fig 10 5 Lay Surround sides flat on floor and align with Surround Top H Square the surround by aligning edges...

Page 11: ...ecuring the fan bracket to the stove using a 7 16 socket or wrench Reverse steps 1 2 to install new fan Fig 17 7 Install fan shield as shown in Fig 13 Be sure to place the air inlet opening against th...

Page 12: ...nd side If required it can be relocated to the left side by following the instructions below To make this as easy as possible it is suggested that this be done prior to fitting the surround and instal...

Page 13: ...Wire placement is important to prevent damage to wires 7 Remove the control assembly from the ashlip bracket on the right hand side Flip it over and reattach on the left hand side of the ashlip Fig 2...

Page 14: ...waste of fuel Too slow a burn contributes to creosote buildup and lowers combustion efficiency Lighting a Fire WARNING Never use chemicals or any other volatile liquid to start a fire 1 Adjust air co...

Page 15: ...setting other than for starting or preheating fresh fuel loads DO NOT OVERFIRE THIS HEATER Attempts to achieve heatoutputratesthatexceedheaterdesignspecifications canresultinpermanentdamagetotheheater...

Page 16: ...C22 1 Canadian Electrical Code and in the USA withtheNationalElectricalCode ANSI NFPA70 latestedition Chimney Smoke and Creosote Formation When wood is burned slowly it produces tar and other or ganic...

Page 17: ...ler The size required is 11 3 8 x 17 1 4 x 5 mm Ceramic glass must be used Do not substitute with any other type To remove broken glass undo the four retaining screws and remove the clamps noting posi...

Page 18: ...el ALT5 P50274723BK Ashlip Assy Majolica Brown Enamel ALT5 P50374723BN Ashlip Assy Antique White Enamel ALT5 P50374723AW Replacement Parts WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION 2 3 4 1 5...

Page 19: ...igh mass weight acts as a heat storage and the thermalinsulationkeepsthecombustionzonehot Active flamingtakesplaceduringthefirstpartoftheburn During this stage heat is stored in the mass of the unit a...

Page 20: ...ee 1 2 and 3 above 2 Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete...

Page 21: ...a T5 Insert Firebrick Installation This package contains 18 full size firebricks as well as 1 cut size brick With the heater in the upright position install firebricks as follows Place firebricks on t...

Page 22: ...ectly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required to be returned to Paci...

Page 23: ...UENTLY UNDER CER TAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY MADE IN CANADA F M A M J J A S O N D 2010 2011 2012 2013 2014 2015 U S ENVIRONMENTALPROTECTIONAGENCY CERTIFIED TO COMPLY WITH...

Page 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Technical Support 1 250 748 1184 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Reviews: