ALT5 LE Insert 230819-32
100003038
Ember Protection:
Combustible flooring in front of the fireplace insert must be protected from hot embers by non-combustible
material extending;
• Canada - 18” to the firing side (From the Glass) and 8” to each side of the unit.
• U.S.A. - 16” to the firing side (From the Glass) and 8” to each side of the door opening.
Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, and
N.F.P.A. 211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA.
CAN: 24
7/8
” / 630mm
USA: 22
7/8
”
Masonry Hearth
CAN
18” / 406mm
USA: 16”
Ember
Protection
Figure 4: ALT5 Insert LE - Ember protection.
Optional Leveling Legs
Leveling legs(bolts) are provided if you need them to level or steady the insert on an uneven hearth.
• If you fireplace is lower than the hearth mount the rear leveling leg bolts. Prop the unit up to access
threaded inserts under the sides towards the rear of the unit. Thread supplied bolts into inserts, set depth
to correspond to depth of fireplace drop.
• If your hearth is lower than the fireplace floor install the front leveling bolts. Prop the unit up to access the
threaded inserts under the front, towards the sides of the unit. Thread the supplied bolts into inserts.
•
Push the Insert into position in the fireplace and adjust the leveling bolts as needed to level the Insert.