12"
305mm
10”
254mm
6”
155mm
Adjacent
Wall
Mantel or Top Facing
Side F
acing
Fireplace hearth
Figure 5: Clearances - ALT 5 Insert LE.
14
ALT5 LE Insert 230819-32
100003038
The minimum required clearances to surrounding combustible materials when installed into a masonry or
factory built fireplace are listed below and in Figure 5.
Minimum Clearances to Combustibles:
Side of Blower Cover to Adjacent Sidewall ............................ .......10 in. (245 mm.)
Side of Blower Cover to Side Facing (max 3-1/2 in. deep) ............... 6 in. (155 mm.)
Top of Cast top to Mantel Facing .................................................... 12 in. (305 mm.)
Top of Cast Top to Mantel (max 12in. deep) .................................... 12 in.( 305 mm.)
Clearances
CAUTION: Unit hot while in operation. Parts of the appliance, especially the external surfaces,
will be hot to touch when in operation. Keep children, clothing and furniture away.
Contact may cause skin burns.