background image

23

Label

FOR USE WITH/

NATURAL GAS/

LP-GAS/

EN CASE D’EMPLOI AVEC:

DU GAZ NATUREL DU GAZ LP

Minimum supply pressure / Pression minimum d’alimentation:

5.0 in/wc / 5.0 po/c.e.

11.5 in/wc / 11.5 po/c.e.

(For the purpose of input adjustment/dans le but de regler l’alimenation)

(1.25 kPa)

(2.86 kPa)

Manifold pressure / Pression de la tuyauterie:

3.8 in/wc / 3.8 po/c.e.

11.0 in/wc / 11.0 po/c.e.

(.95 kPa)

(2.74 kPa)

Orifice Size /  Diametre de l’injectuer:

3/32" (2.38 mm)

1.45 mm

Input BTU/hr (kW)  /  Puissance à l'entrée BTU/h (kW) :

Max.: 27,000

(7.9)

Max.: 25,000

(7.3)

Min.: 13,500

(4.0)

Min.:

12,500

(3.7)

Output BTU/hr (kW)  /  Puissance fourmie BTU/h (kW)

- Fan On / Ventilateur ouvert

20,520

(6.0)

19,375

(5.7)

- Fan Off / Ventilateur position éteinte

19,116

(5.6)

18,500

(5.4)

Optional components:  Blower Kit (MINB.BLOW) / Éléments facultatifs:  Ventilateur (MINB.BLOW)

Blower electrical rating:  115v, 60hz, 0.5 A / Normes electriques du ventilateur:  115v, 60hz, 0.5 A

This appliance equipped for altitudes 0-4500 ft. (0-1370 m) / Cet unité est concu pour des altitudes variant entre 0- 4500

pieds (0-1370 m). Also certified for installation in a bedroom or a bedsitting room / Aussi certifié pour installation dans

une chambre à coucher ou une salle de séjour.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion

and ventilation air.  Par mesure de securite, cet appareil doit etre installe de facon a assurer un approvisionnement

suffisant d’air de combustion et de ventilation.

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

Refer to the owner’s information manual provided with this appliance.   For assistance or additional information, consult

a qualified installer, service agency or the gas supplier.
This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN/CGA-B149

(Canada) or ANSI Z223.1 (USA). Cet appareil diot etre installe conformement aux exigences des codes locaux.  S’il

n’existe aucun code local, se conformer a la norme CAN/CGA-B149 en vigueur.
Left and Right side are determined when facing the front of the appliance.

Les cotes droit et gauche se determinent en se mettant devant l’appareil et en lui faisant face.
INSTALL IN SOLID FUEL BURNING  FIREPLACE / N'INSTALLER QUE DANS UN FOYER NON COMBUSTIBLE

Use Optional Zero Clearance Kit (MINB.ZCKIT) for Zero Clearance Installation / Utilisez Nulle trousse du Dégagement

pour Nulle Installation du Dégagement à Optional (MINB.ZCKIT).

MINIMUM CLEARANCES TO COMBUSTIBLES /

Fireplace Insert /

Optional Zero Clearance Kit /

DEGAGEMENT DES MATIERES INFLAMMABLES

Encart de la cheminée

Nulle trousse du

Déblaiement facultative

Adjacent Sidewall / Mur du côté adjacent :

9.5 in. / 9.5 po.

(241 mm)

7.5 in. / 7.5 po.

(191 mm)

Ceiling / Plafond :

38 in. / 38 po.

(965 mm)

34 in. / 34 po.

(864 mm)

Mantel to Appliance / Du manteau al’appareil :

11 in. / 11 po.

(279 mm)

12 in. / 12 po.

(305 mm)

Max. Mantel Extension / Extension max. dmanteau :

*4 in. / 4 po.

(102 mm)

9.5 in. / 9.5 po.

(241 mm)

      *See Installation Manual for more detail / Voyez

        des Directive de l'Installation pour plus détaux

Facing Side and Top / :

1 in. / 1 po.

(25 mm)

Floor / Sol

-unprotected (in Canada) / sans protection (au Canada) :

1.5 in. / 1.5 po.

(38 mm)

-unprotected (in U.S.A.) / sans protection (dans U.S.A.) :

5.5 in. / 5.5 po.

(140 mm)

-protected with Wonder Board / protégé avec “Wonder Board” :

0 in. / 0 po.

(0 mm)

Mantel Supports (Max. 3.5 in. Ext.)  / Supports du manteau (Max. 3.5 po. Extension) :

3.5 in. / 3.5 po.

(89 mm)

Vent Pipe / Déchargez le Tuyau :

1 in. / 1 po.

(25 mm)

Top, Back and Side Standoffs / Sommet, Arrière et Côté Standoffs :

0 in. / 0 po.

(0 mm)

301000

5050.7202

1-BWGA-1

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

PO Box 1060, Duncan, British Columbia, V9L 3Y2

MODEL / MODELE:

  

BRENTWOOD - INSERT

   

SERIES / SERIE:

  

 A

ANSI Z21.88b-1999 / CAN 2.33b-M99  Vented Gas Fireplace

Heaters,  CAN/CGA-2.17 -M91 Gas-Fired Appliances For Use

At High Altitudes

REPORT NO.

476-1862-00

L18582

VENTED GAS FIREPLACE HEATER - NOT FOR

USE WITH SOLID FUEL

FOYER AU GAZ À ÉVACUATION - NE PAS

UTILISER AVEC DU COMBUSTIBLE SOLIDE.

CERTIFIED FOR CANADA AND U.S.A. / CERTIFIÉ POUR CANADA ET U.S.A.

WH

WH

DO NOT REMOVE OR

COVER THIS LABEL

MADE IN CANADA  /  FABRIQUE AU CANADA

Summary of Contents for Brentwood Gas Insert

Page 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas su...

Page 2: ...8 Surround Assembly 9 Log Set 10 Glowing Embers 12 Levelling Legs 12 Glass Frame Installation 12 Louver Installation 13 Optional Radiant Overlay 13 Lighting Instructions 14 First Fire 15 Operation 15...

Page 3: ...e your Pacific Energy Brentwood Gas Insert without first reading and understanding this manual Any installation or opera tional deviation from the following instructions voids the Pacific Energy Gas S...

Page 4: ...any gas control which has been under water Glass Panel Warning Do not operate appliance with glass panel re moved cracked or broken Replacement of the glass panel should be done by a licensed or qual...

Page 5: ...nstallation code in Canada or the National Fuel Gas Code ANSI Z223 1 1988 in the USA and approved per local codes Only qualified licensed or trained personnel should install this product Only listed t...

Page 6: ...o combustible surfaces are shown on Fig 5 and 6 Adequate clearances aroundairopeningsandcombustionairsuppliesarerequired Fig 6 Fig 5 Minimum Clearances to Combustibles installed as a fireplace insert...

Page 7: ...ply Caution The gas line should be installed by a qualified service person in accordance with all building codes Consult local and or national building codes before pro ceeding The gas valve inlet acc...

Page 8: ...nce 4 Position the spill switch over the two holes and fasten in place with the two screws Fig 9 5 Install surround assembly Connect remaining wire leads to the rocker switch on the surround trim Draf...

Page 9: ...at the joint 3 Assemble the three trim pieces using the enclosed hard ware Slide Part F into the back corners of the trim and tighten screws Ensure the mitred corners fit tightly and evenly Fig 13 4...

Page 10: ...connections should be made before installing logs All logs are numbered on the underside for their order of assembly Position the logs as indicated by pictures below Notches on the underside of logs 2...

Page 11: ...11 Step 7 Rear Right Log Placement log 7 Step 6 Rear Left Log Placement log 6 2 7 5 3 6 4 Fig 17f 1 Step 5 Top Right Log Placement log 5 Fig 17e Fig 17d...

Page 12: ...rner and fan cover may be removed to access the weld nuts from inside Fig 18 The legs thread into the nuts and protrude out the bottom raising the rear of the appliance until it is level with the fron...

Page 13: ...y The optional Radiant Overlay may be installed at any time Unpack and inspect all parts Install Overlay as follows 1 Remove the glass frame as outlined in Glass Frame Removal section Place face up on...

Page 14: ...and call your service technician or gas supplier 9 Turn gas control knob counter clockwise to On position 10 Turn HI LO burner control knob to desired setting 11 Close bottom grill and turn on the bur...

Page 15: ...valve behind the bottom louver as shown in Fig 26 Pulling the rod forward closes the shutter and increases the flame Manual HI LO Flame Adjustment Fig 25 The HI LO burner control knob can be rotated i...

Page 16: ...ft up and forward to disengage from the top frame tabs Placetheglassframeassemblyinasafeplaceto avoid damage 3 Notelogspositionandcarefullyremove taking care not to damage them 4 Remove glowing embers...

Page 17: ...nt com pound to the orifice threads to ensure a good seal into the manifold Fig 31 Pilot Orifice 1 Pull the pilot hood assembly up and off to gain access to the pilot orifice Fig 32 33 2 Remove the or...

Page 18: ...Electrical Code and in the USA with the National Electrical Code ANSI NFPA 70 latest edition Installation The burner assembly must be removed for blower kit installation Follow BurnerRemoval sectionf...

Page 19: ...replaced Fig 37 6 Slide 1 2 grommet with wires into the key hole provided on the fan cover Fig 38 Note Ensure that wires are not touching the bottom of the burner as damage could occur 7 Replace fan...

Page 20: ...ard size MINC 1658_ _ Surround Side Left met black std size MINC 16581MB Surround Side Left embossed BWGA 16582_ _ Surround Side Left over size MINC 1661_ _ Surround Side Left met black over size MINC...

Page 21: ...21 Fig 40 11 14 20 5 13 9 17 2 5 4 19 1 16 15 8 6 10 7 12 5 18 3 14...

Page 22: ...iter 5016 5 7 Valve Cover MIND 186201 8 Manifold 5012 51 9 Burner Orifice 3 32 5021 31 10 Andiron Assembly BRNA 198531 11 Venturi Tube Assembly BRNA 501131 12 Air Shutter Rod 1752 13 Venturi Tube Gask...

Page 23: ...codes locaux S il n existe aucun code local se conformer a la norme CAN CGA B149 en vigueur Left and Right side are determined when facing the front of the appliance Les cotes droit et gauche se dete...

Page 24: ...Printed in Canada Pacific Energy Fireplace Products Ltd Box 1060 Duncan BC V9L 3Y2 Phone 250 748 1184 Web site http www pacificenergy net...

Reviews: