background image

B

This Appliance is Equipped For Use With  /

Cet Appareil est Équipé Pour Utilise Avec :

NATURAL GAS

LP-GAS

GAZ NATUREL

LP GAZ

FOR USE WITH/
EN CASE D’EMPLOI AVEC:

NATURAL GAS/
DU GAZ NATUREL

LP GAS/
DU GAZ LP

Minimum supply pressure / Pression minimum d’alimentation: 

(For the purpose of input adjustment / dans le but de régler l’alimenation) 

Maximum supply pressure / Pression maximum d’alimentation:

Manifold pressure / Pression de la tuyauterie:

Maximum

5.0 in/wc / 5.0 po/c.e.

(1.25 kPa)

13.9 in/wc / 13.9 po/c.e.

(3.45 kPa)

3.5 in/wc / 3.5 po/c.e.

(.87 kPa)

12.5 in/wc / 12.5 po/c.e.

(3.11 kPa)

13.9 in/wc / 13.9 po/c.e.

(3.45 kPa)

10.0 in/wc / 11.0 po/c.e.

(2.74 kPa)

Orifice Size / Diametre de l’injectuer:

2.55mm

1.52mm

Input BTU/hr (kW) / Entree BTU/h (kW):

Max.:30,000Btu (8.8kw) 

Min.: 22,000Btu (6.5kw)

Max.:26,000Btu (7.6kw) 

Min.: 20,000Btu (5.9kw)

VENTED GAS FIREPLACE - NOT FOR USE
WITH SOLID FUEL///FOYER AU GAZ À ÉVACUATION -
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE

ANSI Z21.88-2014 / CSA 2.33-2014 Vented Gas Fireplace Heaters
CAN/CGA 2.17-M91 Gas-Fired Appliance For Use At High Altitudes.

Certified for / Certifié pour Canada and U.S.A.

LC-

209

MODEL/ 
MODELE:

CAMDEN

SERIES/ 
SERIE:

MADE IN CANADA
FABRIQUE AU CANADA

Unit electrical rating: 115v, 60hz, 0.52A / Normes electriques du unité: 115v, 60hz, 0.52 A
This appliance equipped for altitudes 0 - 4500 ft. (0 - 1372 m) / Cet unité est conçu pour des altitudes variant entre 0 - 4500 pieds (0 - 1372 m). In Canada, also
certified for installation in a bedroom or a bedsitting room / Aussi certifié pour installation dans une chambre à coucher ou une salle de séjour. This appliance
must be installed in accordance with local codes, if any; if none, follow the current CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA) Installation Codes. Installer
l’appareil selon les codes ou règlements locaux, ou, en l’absence de tels règlements, selon les codes d’installation CAN/CGA-B149 (Canada), or ANSI Z223.1
(USA) en vigeur.

MANUFACTURED (MOBILE) HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, 
permanently located, manufactured (mobile) home where not prohibited by local codes. See owners manual for details.
FABRIQUEZ (MOBILE) MAISON: Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une 
maison préfabriquée (mobile) installée à demeure si les règlements locaux le permettent. Voir la notice du propriétaire pour plus de détails. Cet appareil ne 
peut être converti à d’autres gaz sauf si une trousse de conversion certifiée est utilisée.
Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH (in CANADA), and the Manufacturer’s Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA
501A, (in the U.S.A.). Cet appareil diot être installé conformemént aux exigences de la norme CAN/CSA Z240 MH en vigueur de l’ACNOR, Installations de gaz
dans les Constructions Mobiles.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY / POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC
L’APPAREIL

MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE
Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent
en se mettant devant l’appareil et en lui faisant face.

For installation in a masonary fireplace only / Pour une installation dans

un foyer maçonnerie seulement

0 in.

(0 mm)

Sidewall to Appliance / Du mur latéral a l’appareil

8 in.

(203 mm)

Mantel to Appliance / Du manteau al’appareil

* SEE  USER MANUAL

Maximum Mantel Extension / Allongement maximum du manteau

*12 in.

(305 mm)

*See Installation Manual for more detail / Voyez des Directive
de l’Installation pour plus détaux.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a 
qualified installer, service agency or the gas supplier.
AVERTISSEMENT: Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer 
des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des 
renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz.

Pacific Energy

Fireplace Products Ltd. 

Duncan, British Columbia, 

Canada

5050.635-B                                                                                         CMDN.BODYB

     

 

120515

CASC.BODYB
CMDN.BODYB

Installer Information

 Camden Rating Label 

41

5055.634-B

251115-44

Summary of Contents for CASCO

Page 1: ...ervice must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may...

Page 2: ...STRUCTIONS 14 Installer Information FIREPLACE DIMENSIONS 15 FIREPLACE FRAMING DIMENSIONS 16 CLEARANCES TO COMBUSTIBLES 17 LOCATING THE FIREPLACE 18 VENTING 19 DAMPER POSITION 19 VENT TERMINAL MINIMUM...

Page 3: ...f 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the...

Page 4: ...e hazardous This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kP...

Page 5: ...viewing glass is provided with the appliance and shall be installed If the barrier becomes damaged the barrier shall be replaced with the manufactures bar rier for this appliance Any grill panel or do...

Page 6: ...t Before operating your fireplace carefully read this manual and pay close attention to all Safety Warnings The manual contains important information on the unit s safe operation and maintenance When...

Page 7: ...ansmitter 2 Proflame2 Integrated Fireplace Control IFC board and a wiring harness to connect the IFC to the gas valve and stepper motor Transmitter Remote Control with LCD Display The Proflame 2 Trans...

Page 8: ...e IFC allowing the batteries to be used only when line power is interrupted or lost and if the Fireplace does not use a combustion fan Operating Procedure Initializing the System for the first time 1...

Page 9: ...ireplace With the system ON press the ON OFF Key on the Remote transmitter The Remote transmitter LCD display will only show the room temperature Figure 6 or Figure 7 At the same time the Receiver mod...

Page 10: ...Thermostat key Figure 1 The LCD display on the transmitter will change to show that the room thermostat is ON and the set temperature is now displayed Figure 10 To adjust the set point press the up o...

Page 11: ...index to the fan control icon Figure 13 Use the Up Down Arrow Keys Figure 1 to turn on off or adjust the fan speed Figure 13 A single beep will confirm reception of the command Continuous Pilot Inter...

Page 12: ...stat set point etc When the IFC batteries are low a double beep will be emitted from the IFC module when it receives a command from the remote This is an alert for a low battery condition for the IFC...

Page 13: ...and burner assemblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean burners with a brush or vacuum clean...

Page 14: ...power to the fireplace and call your service technician or gas supplier Note Sufficient time must be allowed for air to escape from lines if the unit is being lit for the first time 4 Push the On Off...

Page 15: ...FIREBOX WIDTH Figure 17 Camden dimensions Figure 18 Camden lintel and facing CASC BODYB CMDN BODYB Installer Information Fireplace Dimensions FRAMING NOTE A sheet of non combustible material must be u...

Page 16: ...sco corner framing Figure 22 Camden corner framing CASC BODYB CMDN BODYB Installer Information 31 1 2 800mm 36 3 4 933mm 20 7 8 530mm 39 1 2 1003mm 39 3 4 1010mm 20 7 8 530mm Figure 19 Casco framing d...

Page 17: ...30 Minimum Clearance to Combustible Materials NCR stands for No Clearance required You may use combustible materials in direct contact with the appliance on these surfaces Clearances to Combustibles L...

Page 18: ...ecessary to determine where the unit is to be installed location of vent system and where gas supply piping may be plumbed Various installations are possible such as into an existing wall a corner a b...

Page 19: ...tting may need slight adjustment from this chart Note The vent must not exceed a total length of 35 feet Any combination of rise and run may be used but must be constrained to the boundaries of this c...

Page 20: ...grass top of plants wood combustible veranda porch deck or balcony B 12 inches 30 cm min Clearance beside or below a window or door that may be opened C 12 inches 30 cm min Clearance to permanently cl...

Page 21: ...cription ICC EXCELDirect Metal Fab Sure Seal Security Secure Vent Selkirk Direct Temp DuraVent DirectVent Pro Galvanize d Black Galvanized Black Galvanized Black Galvanized Black Galvanized Black 6 Pi...

Page 22: ...see the gas supply section for requirements of the gas supply A gas shut off valve is located inside the fireplace and may be accessed by removing the inner firebox unit Electrical connection Open the...

Page 23: ...s installing this appliance Consult local and or national building codes before proceeding Gas supply line connection is located on the side of the fireplace Gas connection accepts a NPT fitting Corre...

Page 24: ...es with the fireplace lit and at the highest setting 1 Remove bottom trim and locate the valve as seen in Figure 32 2 Locate the inlet and outlet test points on the valve which can be seen in Figure 3...

Page 25: ...connecting all four of its hooks to the lintels four tabs Figure 35 Figure 34 Surround Figure 35 Surround and lintel tab Figure 36 Top of surround fitting inside the baffle during installation Figure...

Page 26: ...CSGB PowdercoatSilver Grey BDCD 30LFBKB Black BDCD 30LFGYB Grey BDCD 30LFPCBKC PowdercoatBlack BDCD 30LFPCCUB PowdercoatCopper BDCD 30LFPCSGB PowdercoatSilver Grey CAMDEN LOUVERED FRONT CASCO CONTOURE...

Page 27: ...e removed using a socket Before installing the new orifice Thread Sealant needs to be applied to the threads of the new orifice to ensure a proper seal when installed To replace the pilot orifice you...

Page 28: ...Remove surround from lintel by lifting it from 4 tabs located on the lintel Figure 42 2 Locate and remove the two 3 8 bolts securing the bottom of door as seen in Figure 43 3 Tilt the bottom of the d...

Page 29: ...baffle and remove the baffle Figure 48 3 Remove two screws from the burner plate Figure 49 and remove burner plate 4 Remove the side and rear firebox panels Figure 50 and Figure 51 Remove panels to pr...

Page 30: ...ng attached 5 Remove two screws which hold the back ledge Figure 52 in place and remove 6 Remove the approximately 25 screws hold the base plate Figure 53 to the frame of the firebox 7 Gently remove t...

Page 31: ...he fire box Figure 56 Be careful not to accidentally catch any other wires while the fan is being extracted 9 Disconnect the two power wires Figure 57 before fully extracting the fan from the opening...

Page 32: ...use two screws to secure the front of the baffle to the top of the firebox seen in Figure 61 Panel Removal 1 Remove the baffle by removing screws securing the front edge of the baffle Figure 61 After...

Page 33: ...Figure 62 using a screwdriver and remove the air deflector from fireplace Burner Tray Installation Removal Installation Place the burner tray in the fireplace and secure with 4 screws using a screwdr...

Page 34: ...st behind the front burner tube Figure 68 3 Position log 3 decorative log with the thin end of the log resting on top of the right end of the front log Figure 69 4 Place ember chunks in front of the f...

Page 35: ...inst the back firebox Figure 73 2 Position front logs 3 and 4 between the front burner tubes Figure 74 3 Position side logs 5 6 Figure 75 4 Position logs 7 and 8 Figure 76 5 Place logs 9 10 and 11 and...

Page 36: ...ass Burner Kit Screw locations Screw locations Pilot Collar The glass burner plate comes with a collar for the pilot screws to secure the burner tray to the firebox and and a bag of glass Figure 78 Ca...

Page 37: ...ficient air supply to the fire which would result in flames that cause soot See Damper Position on page 19 for optimum damper position To adjust the damper loosen the two screws that hold the air defl...

Page 38: ...Rustic Log Set BDEM NG05B Glass Burner BDEM NG03B Black Glass GASC 3GLBK Desert Glass GASC 3GLDE Pacific Glass GASC 3GLPA Twilight Glass GASC 3GLTW Metro Rock Set Black GASC METROBKA Metro Rock Set G...

Page 39: ...DN BODYB Installer Information Wiring Diagram Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation af...

Page 40: ...type de gaz indiqu sur la plaque signal tique et peut tre install dans une maison pr fabriqu e mobile install e demeure si les r glements locaux le permettent Voir la notice du propri taire pour plus...

Page 41: ...type de gaz indiqu sur la plaque signal tique et peut tre install dans une maison pr fabriqu e mobile install e demeure si les r glements locaux le permettent Voir la notice du propri taire pour plus...

Page 42: ...CASC BODYB CMDN BODYB Installer Information 42 251115 44 5055 634 B...

Page 43: ...CASC BODYB CMDN BODYB Installer Information 43 5055 634 B 251115 44...

Page 44: ...LTD For technical support please contact your retailer Web site www pacificenergy net 2975 Allenby Rd Duncan BC V9l 6V8 Reproduction adaptation or translation without prior written permission is proh...

Reviews: