Chimney
Storm collar
* 4"(102mm) diameter air inlet with rodent screen
* If the crawl space is well ventilated it is not
necessary to extend air inlet to outside
Spark arrestor
rain cap
Radiation shield
Chimney Connector
Chimney Support
56" (1422 mm)
Minimum
Minimum 7' (2.1m.)
Ceiling Height
Non-combustible
floor protector
48"
(1219 mm)
3' (914 mm)
Minimum
Hooded vent or
90 elbow turned down
The chimney may incor-
porate an offset. To do
this safely, all sections
of listed connector, off-
set elbows and chim-
ney section must be
screwed together by at
least three sheet metal
screws per joint. The
chimney must be suit-
ably supported by the
chimney manufacturer's
listed offset support.
Roof flashing
Attachment to floor for
mobile homes
Figure 6: Mobile home installation.