Procedure
1. If a listed chimney and double-wall connector is to be connected to the stove, install all components to
the chimney manufacturer's installation requirements. (Outside combustion air may be required, consult
local building codes. See Combustion Air section.)
2. If it is desirable to use smoke pipe in conjunction with the insulated chimney, see step 4.
3. If a roof or ceiling support is used in the installation, you will find the chimney manufacturer's complete
instructions packed with the roof support.
4. To start installing smoke pipe (chimney connector), slip crimped edge of the pipe inside the stove collar.
Use holes provided in collar to secure pipe with two screws.
5. Install the remaining lengths of pipe one on top of the other to the finished height of the chimney connec-
tor and secure to each other.
Floor Protector
16" [406mm]
8" [203mm]
8" [203mm]
U.S.A. Only
Minimum Width - 34"(864mm)
Minimum Overall Depth - 40 1/2"(1.03m)
Non-combustible
floor protector
Figure 7: Floor protector - USA only.
The stove may be installed on a combustible floor provided noncombustible ember protection is used.
This protection must extend as follows:
In USA: 16" (406 mm) to the front and 8" (203 mm) to the sides of the fuel loading door opening. See Figure
#4, below. This protection is also required under the chimney connector and 2" (51 mm) beyond each side.