PLEASE SAVE THESE INSTRUCTIONS

This manual describes the installation and operation of the 
Pacific Energy, NEO 1.2 Freestanding wood heater. 

This heater meets the 2015 U.S. Environmental Protection 
Agency's crib wood emission limits for wood heaters sold 
after May 15, 2015. Model NEO1.2: 2.9 g/hr.

Under specific test conditions this heater has been shown 
to deliver heat at rates ranging from 11,700 to 22,400  
Btu/hr.

SAFETY NOTICE:  If this stove is not properly installed, 
a house fire may result. For your safety, follow the 
installation instructions. Contact local building or fire 
officials about restrictions and installation inspection 
requirements in you area.

Please read this entire manual before you install and use 
your new room heater. Failure to follow instructions may 
result in property damage, bodily injury, or even death.

EPA Certified Emissions

2.9 grams per hour

LHV Tested Efficiency 1

79.6%

HHV Tested Efficiency 2

73.7%

EPA BTU Output 3

11,700 to 22,400 btu/hr

Peak BTU/Hr Output 4

29,700

Maximum Wood Length

17 inches

Ideal Wood Length 

16 inches

Fuel

Seasoned Cord wood

1 Weighted Average Lower Heating Value (LHV) efficiency as 
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is 
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efficiency 
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required 
to vaporize the water in the fuel
 3 The range of BTU outputs is based on efficiency using CSA 
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using 
Douglas Fir dimensional lumber.
4 The Peak BTU/hr is based on efficiency using CSA B415 
Performance testing of solid-fuel-burning heating appliances, 
the Maximum one hour High burn rate from the High Burn EPA 
test and the BTU content of cord wood (8600 btu/lb).

Efficiency and BTU Output

Experience will give you the right settings for proper combustion and efficient burning. Remember the correct air inlet 
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions.  With 
practice, you will become proficient in operating your heater and will obtain the performance for which it was designed.

CERTIFIED FOR CANADA

 AND U.S.A. 

 - SERIES / SÉRIE: 

D

   MODEL

 / MODÈLE:  

 

SUPER 27 

     SPECTRUM 

 

   

ALDERLEA

 T5 

 

 

  CLASSIC 

LISTED ROOM HEA

TER, SOLID FUEL

 TYPE.

ALSO FOR USE IN MOBILE HOMES. TESTED T

O/ ÉPROUVÉ SELON: CAN/ULC S627-00 / CONFORMS 

TO

 UL

 1482-201

    

        

 

• 

INST

AL

AND USE IN 

ACCORDANCE WITH THE MANUF

ACTURER’S INST

ALLA

TION 

AND OPERA

TING 

 

INSTRUCTIONS.

• 

CONT

ACT LOCAL

 BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS, INST

ALLA

TION PERMIT 

AND 

 

INSPECTION IN 

YOUR 

AREA.

• 

DO NOT CONNECT THIS UNIT 

TO

 A 

CHIMNEY

 FLUE SER

VING 

ANOTHER 

APPLIANCE (USA. ONL

Y).

• 

USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECT

OR

.

• 

CAN BE CONNECTED 

TO

 A 

LINED MASONR

CHIMNEY

 SUIT

ABLE FOR USE WITH SOLID FUELS.

• 

DO NOT OBSTRUCT THE SP

ACE BENE

AT

H THE HE

AT

ER

.

• 

SEE LOCAL

 BUILDING CODE 

AND MANUF

ACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED

 

WHEN P

ASSING 

CHIMNEY

 THROUGH 

COMBUSTIBLE 

WA

LL

 OR CEILING.

• 

DO NOT 

PA

SS 

CHIMNEY

 CONNECT

OR THROUGH 

COMBUSTIBLE 

WA

LL

 OR CEILING.

• 

MINIMUM CLEARANCE BETWEEN SINGLE 

WA

LL

 CHIMNEY

 CONNECT

OR 

AND COMBUSTIBLE MA

TERI

-

ALS-18INCHES/455MM.  CLEARANCE MA

BE REDUCED BY

 THE USE OF LISTED PIPE SHIELDS, 

WA

LL

 

PROTECT

ORS OR OTHER MEANS 

APPROVED BY

 LOCAL

 BUILDING OR FIRE OFFICIALS.

• 

COMPONENTS REQUIRED FOR MOBILE HOME 

AND 

ALCOVE INST

ALLA

TION: OUTSIDE 

AIR KI

T.

 B

OTH CHIMNEY

 SYSTEM 

AND CONNECT

OR MUST BE LISTED 

TO

:

  

IN CANADA

 -  ULC S-641 LISTED CONNECT

OR 

AND ULC-S-629 LISTED CHIMNEY

  

IN US

-  UL-103 HT LISTED CONNECT

OR 

AND CHIMNEY

 

• 

USE COMPONENTS SPECIFIED IN P

ACIFIC ENERGY

 INST

ALLA

TION INSTRUCTIONS.

• 

APPLIANCE MUST BE INST

ALLED WITH PEDEST

AL

 OR LEG KIT 

AT

TACHED.

• 

OPTIONAL

 COMPONENTS - F

AN KI

T,

 F

AN ELECTRICAL

 RA

TING: 1

15V

, 60HZ, 1.0 

AM

P.

• 

CAUTION: RISK OF EXCESSIVE TEMPER

AT

URES - KEEP

 ASH DUM

CLOSED DURING FIRING OF THE 

HEA

TER. • DO NOT ROUTE POWER CORD UNDER HEA

TER. 

• 

OPER

AT

E ON

LY

 WITH FEED DOOR CLOSED.  OPEN 

TO

 FEED FIRE ON

LY

.

• 

KEEP

 FURNISHINGS 

AND OTHER COMBUSTIBLE MA

TERIALS WELL

 AW

AY

 FROM HE

AT

ER

.

• 

REPLACE GLASS ON

LY

 WITH CERAMIC GLASS.

 

HORIZON

TA

CONNECT

OR NOT PERMITTED IN MOBILE HOMES

 

AS TESTED - PIPE SHIELD MA

BE REQUIRED BY

 LOCAL

 AUTHORITIES.

ALCOVE SIZE : DEPTH - 3 FT

. / .91 M MAX., HEIGHT 7 FT

. / 2.1 M MIN., WIDTH 4 FT

. / 1.2 M MIN.

 

COMBUSTIBLE FLOOR MUST BE PROTECTED BY

 A 

CONTINUOUS NON-COMBUSTIBLE MA

TERIAL

 EX-

TENDED 

TO

 THE FRONT

, SIDES 

AND BACK 

AS INDICA

TED.

•   THIS WOOD HEA

TER NEEDS PERIODIC INSPECTION 

AND REP

AIR FOR PROPER OPERA

TION. - CONSUL

THE OWNER’S MANUAL

 FOR FURTHER INFORMA

TION. • IT IS 

AGAINST FEDERAL

 REGULA

TIONS 

TO

 

OPERA

TE THIS WOOD HEA

TER IN 

MANNER INCONSIST

ANT WITH THE OPERA

TING INSTRUCTIONS IN

 

THE OWNER’S MANUAL

 

WN#16408        ETL#4001507

• 

INST

ALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INST

ALLA

TION ET D’OPÉR

AT

ION FOURNI 

AVEC 

L’APP

AREIL..

• 

CONT

ACTEZ LES OFFICIELS DE LA

 CONSTRUCTION OU DE SER

VICE D’INCENDIE POUR DES INFORMA

TIONS QUANT 

AUX

 

RESTRICTIONS. PERMIS D’INST

ALLA

TION ET INSPECTIONS DANS VOTRE RÉGION.

• 

NE RELIEZ 

PA

S CET 

APP

AREIL

 À UN CONDUIT DE CHEMINÉE DESSER

VANT DÉJÀ UN 

AUTRE 

APP

AREIL

 (ÉT

AT

S-UNIS SEULE

-

MENT).

• 

UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET 

AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm

.

• 

PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE 

ALIGNÉE PRÊTE À 

L’EMPLOI 

AVEC DES COMBUSTIBLES SOLIDES.

• 

DO NOT OBSTRUCT THE SP

ACE BENE

AT

H THE HE

AT

ER / 

• 

CONSUL

TEZ LE CODE LOCAL

 DE CONSTRUCTION ET LES INSTRUCTIONS DU 

FA

BRICANT QUANT 

AUX PRÉCAUTIONS À 

PRENDRE LORSQUE VOUS F

AITES P

ASSER UNE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MA

TÉ-

RIAUX COMBUSTIBLES.

• 

NE 

FA

ITES 

PA

PA

SSER UN RACCORDEMENT DE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MA

-

RIAUX 

• 

DÉGAGEMENT MINIMA

ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET 

TO

UT MA

TÉRIEL

 COMBUSTIBLE - 18 

POUCES / 455 mm.  CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUY

AUX CLASSÉS, PROTEC-

TEURS DE MUR OU 

AUTRES MOYENS 

APPROUVÉS P

AR LES OFFICIELS DE LA

 CONSTRUCTION OU DU SER

VICE D’INCENDIE 

DE VOTRE RÉGION.

 

CONNECTEUR HORIZON

TA

NON PERMIS DANS MAISONS MOBILE

S

• 

L’

APP

ARIEL

 DOIT COMPORTER UN ENSEMBLE POUR PIEDST

ABLE OU SUR 

PA

TTES.

• 

PIÈCES REQUISES POUR INST

ALLA

TION EN MAISON MOBILE OU EN 

ALCÔVE:  NÉCESSAIRE D’APPROVI-

SIONNEMENT D’AIR EXTÉRIEUR ET L

’UN DES RACCORDS SUIV

ANTS:  EN COMBINAISON 

AVEC 

L’

UN DES 

SYSTÈMES DE CHEMINÉE COMP

ATIBLES SUIV

ANTS: 

    

AU CANADA

 - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE

• 

 PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE:  

11

5V

, 60HZ, 1.0 

AM

P.  LE FI

ÉLECTRIQUE NE DOIT P

AS ÊTRE PLACÉ SOUS LE POÈTE.  • LE FIL

 ÉLECTRIQUE NE DOIT P

AS ÊTRE PLACÉ SOUS LE POÊLE

• 

ATTENTION:  RISQUE DE TEMPÉR

AT

URES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT 

L’ALLUMAGE DU 

POÈTE.

• 

OPÉREZ SEULEMENT LORSQUE LA

 PORTE D’ALIMEN

TA

TION EST FERMÉE. • OUVREZ SEULEMENT POUR 

ALIMENTER LE FEU.

• 

GARDEZ LES MEUBLES ET 

AUTRES MA

TÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.

• 

REMPLACES LA

 VITRE 

AVEC UNIQUEMENT DE LA

 VITRE CÉRAMIQUE.

 CONNECTEUR HORIZONT

AL

 NON PERMIS DANS MAISONS MOBILE

S

TEL

 QUO ÉPROUVÉ UN PROTECTEUR DE TUY

AU PEUT ÊTRE REQUIS P

AR LES 

AUT

ORITÉS LOCALES

 * 

DIMENSION D’ALCOVE COMBUSTIBLE:  PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M MINI- MUM.

 

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ P

AR UN MA

TÉRIEL

 NON-COMBUSTIBLE 

TO

UT D’UNE PIÈCE QUI DOIT 

S’ÉTENDRE DE P

AR LE DEV

ANT

, LES COTÉS ET L

’ARRIÈRE TEL

 QU’INDIQUÉ.

    CET 

APPRAREIL

 DE CHAUFF

AGE 

AU BOIS DOIT F

AIRE L

’OBJETD’ENTRETIENS ET D’INSPECTIONS 

RIODIQUES 

POUR UN FONCTIONNEMENT 

AD

ÉQUA

T.

 CONSUL

TEZ LE MANUE

D’UTILIS

AT

ION POUR PLUS D’INFORMA

TION

.

MADE IN CANADA/ 

FABRIQUÉ 

AU CANADA

 

 F 

 M 

 A 

 M 

 J 

 J 

 A 

 S 

 O 

 D

2015 

2016 

2017 

2018 

2019 

2020

DA

TE OF MANUF

ACTURE/ 

DA

TE DE MANUF

ACTURE

SUP1-A2

5050.75

040615

MANUF

ACTURED BY/

 F

ABRIQUÉ P

AR:

PACIFIC ENERGY

 FIREPLACE PRODUCTS 

LT

D.

2975 

ALLENBY

 RD., DUNCAN, BC  V9L

 6V

8

HOT WHILE IN OPERA

TION.  DO NOT T

OUCH.  KEEP

 CHILDREN, CLOTHING 

AND FURNITURE 

AW

AY

.  CONT

ACT MA

CAUSE SKIN BURNS.  SEE NAMEPL

AT

AND INSTRUCTIONS.// 

CHAUD LORSQU’EN OPÉRA

TION.  NE P

AS T

OUCHER, TENEZ LES 

ENF

ANTS ET LES VÊTEMENTS BIEN À 

L’ÉCART

.  LE CONT

ACT PEUT CAUSER DES BRÛLURES 

À LA

 PEAU.  CONSUL

TEZ LA

 PLAQUE CE CONSTRUCTEUR ET LES INSTRUCTIONS.

CAUTION

DO NOT

 REMOVE 

THIS 

LABEL

S/N-

504

U.S. ENVIRONMENT

AL

 PROTECTION 

AGENCY

Certifi

 ed to comply with 2015 P

ARTICUL

AT

E EMISSION ST

ANDARDS. 

Not approved for sale after May15,2020.// 

Certifi

 é conforme aux normes sur les 

émissions de particules de 2015. Non approuvé pour la vente après le 15 Mai 2020.

3.4 g/hr

 A. 

 18 in. / 455 mm 

14 in. / 356 mm

 B. 

 12 in. / 305 mm 

 8 in. / 200 mm

 C. 

 11

 in. / 280 mm 

11

 in. / 280 mm

 D. 

 27 in. / 685 mm 

23 in. / 585 mm

 E. 

 19 in. / 485 mm 

 15 in. / 380 mm

 F.

  22 in. / 560 mm 

22 in. / 560 mm

 A. 

 14 in. / 356 mm 

14 in. / 356 mm

 B. 

 5 in. / 127 mm 

5 in. / 127 mm

 C. 

 4 in. / 102 mm 

4 in. / 102 mm

 D. 

 22.5 in. / 570 mm 

22.5 in. / 570 mm

 E. 

 11

.5 in. / 292 mm 

 11

.5 in. / 292 mm

 F.

  14.5 in. / 370 mm 

14.5 in. / 370 mm

 A. 

 16 in. / 405 mm 

16 in. / 405 mm

 B. 

 10 in. / 255 mm 

8 in. / 200 mm

 C.  

 

N/

8 in. / 200 mm

 D. 

 24.5 in. / 620 mm 

24.5 in. / 620 mm

 E.

 16.5 in. / 420 mm 

14.5 in. / 370 mm

 F.

   

N/

18.5 in. / 470 mm

MINIMUM CLEARANCES 

TO

 

COMBUSTIBLE MA

TERIALS/

DÉGAGEMENTS MINIMALES 

AUX 

MA

TÉRIAUX COMBUSTIBLE

S

 RACCORD

 VERTICAL

 CONNECT

OR     

 RACCORD

 HORIZONT

AL

 CONNECT

OR

  

RESIDENTIAL

 CLOSE CLEARANCE INST

ALLA

TION 

USING DOUBLE W

ALL

 CONNECT

OR/ 

INST

ALLA

TION 

RÉSIDENTIELLE 

AVEC DÉGAGEMENT MINIMAL, UTILISANT

 

UN RACCORD DE MUR DOUBLE

* ALCOVE INST

ALLA

TION

USING DOUBLE 

WA

LL

 

CONNECT

OR/

* INST

ALLA

TION 

EN 

ALCÔVE UTILISANT UN

 

RACCORD DE MUR DOUBLE

RESIDENTIAL

 INST

ALLA

TION 

USING SINGLE W

ALL

 CONNECT

OR/

INST

ALLA

TION RÉSIDENTIELLE UTILISANT UN  RACCORD DE MUR SIMPLE

 IN CANADA

 

G. 

18 INCHES / 455 MM

 AU CANADA

 

H. 

8 INCHES / 200 MM

 

I. 

8 INCHES / 200 MM

 IN U.S.A. 

G. 

16 INCHES / 405 MM

 AUX ÉT

AT

S-UNI

H.

 

5 INCHES / 127 MM

 

I. 

0 INCHES / 0 MM

MOBILE 

HOME INST

ALLA

TION

USING DOUBLE 

WA

LL

 

CONNECT

OR/

 INST

ALLA

TION 

EN MAISON MOBILE UTILISANT  UN RACCORD DE MUR DOUBLE

A. 

SIDEW

ALL

 TO

 UNIT/

 

MUR DE CÔTE / 

APP

AREI

L

B. 

BACKW

ALL

 TO

 UNIT/

M

UR DE FOND / 

APP

AREI

L

C. 

CORNER 

TO

 UNIT/

COIN / 

APP

AREI

L

D. 

SIDEW

ALL

 TO

 CONNECT

OR

/

MUR DE CÔTE / RACCORD E. 

BACKW

ALL

 TO

 CONNECT

OR

/

MUR DE FOND / RACCORD F.

 CORNER 

TO

 CONNECT

OR

/

COIN / RACCORD

BACK  

I

HEA

TER

G

SIDE

H

FRONT

SIDE

H

COTE

COTE

DEV

ANT

POELE

DOS

 RACCORD

 VERTICAL

 CONNECT

OR     

 RACCORD

 HORIZONT

AL

 CONNECT

OR

  

ADJACENT

 W

ALL

BACK W

ALL

D

A

SIDE WALL

B

E

ADJACENT W

ALL

F

C

MUR COTE

MUR 

ARRIERE

MUR ADJACENT

MUR 

ADJACENT

SUPER-SD1_100517-32

3

5055.201

Summary of Contents for Classic Gas

Page 1: ...al building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmental Protection Agency s May 201...

Page 2: ...17 Wood Selection 17 DO NOT BURN 17 How to Test Your Wood 18 Lighting a Fire for the first time 18 Curing of the Paint Finish 18 Lighting a fire 18 Normal Operation 18 Restarting After Extended or Ove...

Page 3: ...PERMIS D INSTALLATION ET INSPECTIONS DANS VOTRE R GION NE RELIEZ PAS CET APPAREIL UN CONDUIT DE CHEMIN E DESSERVANT D J UN AUTRE APPAREIL TATS UNIS SEULE MENT UTILISEZ UN RACCORDEMENT NOIR OU CLASS D...

Page 4: ...building up at least as quickly in the chimney WARNING ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTENANCE OR REPLACEMENTS 4 DOOR GASKETS The gasket used by Pacific Energy 7 8 22mm med...

Page 5: ...This moisture laden smoke cools the chimney compounding the problem by offering the smoke the ideal place to condense In summary a certain amount of creosote is inevitable and must be lived with Regul...

Page 6: ...andle a chimney fire 4 After the chimney fire is out the chimney must be cleaned and checked for stress and cracks before start ing another fire Also check combustibles around the chimney and the roof...

Page 7: ...Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacumn on the grill openings in the back and bottom...

Page 8: ...5 8 702mm 23 5 8 600mm 23 5 8 600mm 23 5 8 600mm 10 254mm 10 254mm 10 254mm 23 7 8 606mm 27 1 2 699mm 29 737mm 29 737mm 27 1 2 699mm 28 1 4 718mm Super 27 Pedestal Super 27 Pedestal Super Classic Figu...

Page 9: ...ash system hole cover and gasket located under the stove Discard cover plate and gasket 2 Inside the stove remove the two bolts for the ash dump from the firebox bottom Figure 2 and insert into the b...

Page 10: ...Brace knockout on page 10 5 Re install the Pedestal Brace with the notched corner to the top left Install the new Ash Pan into the Pedestal 1 2 Leg Model 1 Remove the two screws holding the Leg Ash B...

Page 11: ...to the connector or chimney manufacturer s installation require ments Consult your chimney supplier for installation advice Procedure CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AN...

Page 12: ...14 357mm 26 660mm 16 406mm 18 457mm 22 559mm 28 711mm 8 203mm 8 203mm 8 203mm Alcove Min Height 7 1 2 2 29m Max Depth 4 1 22m 5 127mm 15 381mm Single Wall Connector Residential Double Wall Connector R...

Page 13: ...ible floor protector 48 1219 mm 3 914 mm Minimum Hooded vent or 90 elbow turned down The chimney may incor porate an offset To do this safely all sections of listed connector off set elbows and chim n...

Page 14: ...ram 1 page 6 Chimney and Connector Connect to a listed chimney or a chimney suitable for use with solid fuel that is lined and in good condition and meets local building codes The chimney flue size sh...

Page 15: ...f the pipe inside the stove collar Use holes provided in collar to secure pipe with two screws 5 Install the remaining lengths of pipe one on top of the other to the finished height of the chimney con...

Page 16: ...e and 8 203 mm to the other sides Canada Only 8 203mm 18 457mm 8 203mm 8 203mm Minimum Width 40 1 02m Minimum Overall Depth 50 1 2 1 28m Non combustible floor protector Figure 8 Floor protector Canada...

Page 17: ...outside combustion air for residential installation requires the unit to be secured to the structure to prevent dislodging of the air duct To draw outside air from behind the stove an outside air adap...

Page 18: ...nths or more Wet or undried wood will cause the fire to smoulder and produce large amounts of creosote Wet wood also produces very little heat and tends to go out often DO NOT BURN Salt water wood Gar...

Page 19: ...mm 1 25mm until the wood kindling is fully engulfed in flame 4 After the kindling is fully engulfed add a few small logs Close door 5 Begin normal operation after a good coal base exists and wood has...

Page 20: ...od has approximately 7500 BTU s per pound Experience will give you the right settings for proper combustion and efficient burning Remember the correct air inlet setting is affected by variables such a...

Page 21: ...be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed the...

Page 22: ...up to operating temperature It will also shut the blower off after the fire has gone out and the unit cooled to below a useful heat output range Manual To manually operate the blower set the rocker sw...

Page 23: ...e gasket Check door latch Low Heat Output 1 Wood may be wet Check wood and use drier wood if required 2 Fire too small Build a larger fire Open draft control to increase burn rate 3 Draft too low Chim...

Page 24: ...fic Energy for the location of the dealer nearest you 1 24 25 11 28 18 21 19 1 28 28 2 10 8 9 10 7 6 26 5 4 27 17 3 9 13a 13b 14 14 12 14 15 16 20 28 SUPD LGADA SUPD ASHLEG Replacement Parts Super 27...

Page 25: ...16 Replacement Baffle Kit SSER DBAKIT 17 Baffle Pin SSER 125001 All parts may be ordered from your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer nearest you When...

Page 26: ...ion keeps the combustion zone hot Active flaming takes place during the first part of the burn During this stage heat is stored in the mass of the unit and is later released slowly and evenly As wood...

Page 27: ...ut system or an optional one is being installed save the extra full brick With the heater in the upright position install firebricks as follows Place firebricks on the bottom of the heater first Total...

Page 28: ...th or without an ash dump 2 Once the firebricks for the floor have been laid down the firebricks for the side walls are next The sides use D bricks The bricks will stand on top of the floor bricks and...

Page 29: ...an ash dump use a full size D brick instead of A B firebricks Again the one exception is the C brick D D D Figure 15 Rear wall firebrick installation complete Figure 16 Floor of firebox without ash d...

Page 30: ...Energy s option The defective part may be required to be returned to Pacific Energy or an accredited agent transportation prepaid Porcelain Is warranted for gloss retention Certain colors may darken w...

Page 31: ...SUPER SD1_100517 32 31 5055 201...

Page 32: ...V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada 2017 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written perm...

Reviews: