8
FP16 040515-28
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Baffle Removal
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR
INSULATION REMOVED.
WARNING: AFTER YOU REMOVE THE BAFFLE,
ALWAYS COVER THE TOP OF THE BAFFLE AIR
TUBE LOCATED IN THE REAR OF THE FIREBOX.
THIS PREVENTS DEBRIS FALLING DOWN THE
TUBE. FAILURE TO DO SO WILL RESULT IN POOR
OPERATION AND POSSIBLE DAMAGE TO FIREPLACE
COMPONENTS.
Remove retaining pin located just beneath the baffle at the
rear inside top of the fi rebox. Remove either of the Side Brick
Rails.by; lifting up on the baffle and dis-engaging the rail from
its mounting posts. Lift baffle up and pull forward to disconnect
from the supply tube. Slide the bafl le to one side and then
tilt baffle sideways to drop down and remove from fi rebox. To
re-install the baffle, perform the removal steps in the reverse
order. Ensure that the two side pieces of insulation are set
tight against the baffle. If the insulation is damaged during
removal, it should be replaced.
Secondary Air Box Cleaning
1. The secondary air box access is located on the bottom
rear of the fi replace and can be accessed for cleaning by
removing the two bottom center bricks inside the fi replace
Fig. #1. This will expose the access cover.
2. Remove the screws securing the access cover to the
fi rebox bottom. Inspect airbox for debris. If debris is present,
carefully use a vacum to suck debris through the hole in
the fi rebox bottom.
3. Replace the cover plate and the bricks.
FIG. # 1
COVER
BAFFLE