FP16 040515-28
9
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Glass Cleaning
If glass becomes darkened due to poor burning conditions,
it can be cleaned with fi replace/ceramic glass cleaner when
the fi replace is cold. Never scrape with an object that might
scratch the glass. The type and amount of deposit on the
glass is a good indication of fl ue pipe and chimney buildup.
A light brown dusty deposit that is easily wiped off usually
indicates good combustion and dry, well-seasoned wood and
therefore relatively clean pipes and chimney. On the other
hand, a black greasy deposit that is difficult to remove is a
result of green wood or poor draft. NOTE: This heavy deposit
is building up just as quickly in the chimney.
Blower Replacement
1. Remove the surround front by lifting and pulling away from
the unit. Remove the four screws securing the back sur-
round to the brackets and set the surround aside carefully
to avoid damage.
2. With a 3/8”(10mm) wrench, loosen the two bolts securing
the blower mounting bracket to the unit. Fig. #2
3. Disconnect the two wires leading to the blower motor.
4. Pull the blower mounting bracket bottom out fi rst and
then lift the blower up and back to remove from the bolts.
If replacing the right side blower, then disconnect the two
wires leading to the thermo-switch at this time as well.
5. Remove the three screws securing the blower to the
mounting bracket and replace the blower. Fig. #3
6. Reverse all previous steps to reinstall the new blower.
FIG. # 2
FIG. # 3
BOLTS
SCREWS
FIG. # 4
L2 (neutral)
G (ground)
L1 (hot)
Blowers
Thermo
Switch
Junction
Box
Electrical Rating : 115 V, 60 Hz, 1.1A
To wall
switch/control