8
5055.MR30-A
180516-36
1. Measure chimney height, cut fl ex liner (min.10’
to termination) as required. Mark one pipe at
both ends to identify combustion air intake
pipe from fl ue outlet pipe.
2. Attach marked fl ex liner pipe to the intake side
of vent terminal. Seal and secure with sealant
and screws provided. Attach the other pipe
to the outlet side of vent terminal. Seal and
secure with sealant and screws provided.
3. Insert both fl ex liners from top of the chimney,
down through the damper opening.
4. Before attaching vent terminal to top of chim-
ney, apply a bead of caulking to top of clay
liner. Slip vent terminal over liner and secure in
place with lateral retaining bolts.
5. For larger chimneys, fl ashing will need to be
constructed according to local building codes.
Intake
Air
Exhaust
Air
Co-Linear Venting
Figure 5: Mirage co-linear venting.
NOTE:
If venting the Mirage 30 through an existing
fi replace opening using a co-axial to co-lin-
ear adapter, the customer will have a couple
of aesthetic options which include:
1. sealing up the existing fi replace opening
with a cover or other material, leaving
room in the cover or other material to
accomodate the adapter so that it is
positioned fl ush (Figure 5) with the cover
or other material.
2. Position the Mirage 30 so that it and the
adapter are located outside of the exist-
ing fi replace opening.
Co-Axial to
Co-Linear
adapter
Co-Linear Venting
Notes:
•
Mirage 30 requires a 3
inch diameter exhaust
vent and a 3 inch
intake vent.
•
Max. Vent Height 50’
(15.25M) to termination
•
Min. Vent Height 10’ (3m)
to termination.
High wind cap
Prairie cap
Simpson Duravent High-Wind (cap style) Co-Linear
Kit w/Flex (46DVA-CL34) or Simpson Duravent Prairie
(cap style) Co-Linear Kit w/Flex (46DVA-CL34P) are
recommended for use with this appliance.
Visit http://www.duravent.com for kit details.
^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*
** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the fl oor*
* as specifi ed in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
* for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1