Installation Instructions
Fireclay Flue liner
Concrete cap
Chimney
Approved
Through - Wall
Installation
As per local
and Federal codes
52" (1.32m)
Minimum
Minimum 7' (2.1m.)
Ceiling Height
48"
(1219 mm)
Non-combustible
floor protector
Hooded vent or
90 elbow turned down
*3" diameter air inlet with rodent screen
*If the crawl space is well ventilated it
is not necessary to extend air inlet to
outside
Ensure that the Masonry chimney
meets all National Fire Protection
Association and local building codes.
Have the chimney cleaned and
inspected by a professional to ensure
there are no cracks, weak mortar or
other signs of deterioration. See pipe
manufacturers installation instructions
for further information.
Chimney Connector
12"(305mm)
Minimum first
section of pipe
Figure 12: Venting to a masonary chimney.
21