Replacement Parts

(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM  DESCRIPTION 

PART NO. 

ITEM  DESCRIPTION 

PART NO.

1a..........Side Shield, Left,  ................................... STEP.4303
1b..........Side Shield, Right ................................... STEP.4304  
1c ..........Shield Brackets ...........................................4203.02 
2..............Air Deflector ......................................................229 
3..............Door Catch .........................................WODC.1461
4............Glass Clamps  (4 pc.) ............................ SSER.1425
5............Glass Bar Set  (2 pc.) .........................WODC.41405
6............Replacement Glass  (c/w Tape) ....... DR31.WGLKIT
7............Door Gasket Kit ................................DR31.WDGKIT
8............DoorAssembly ..................................... DR31.WBKA
9............Rear Shield ...................................................... 4201
10 ..........Door Handle Assembly ...................... WODC.4147C
11 ..........Boost Manifold ................................................. 4105
12a ........Firebrick - 1 1/2" x 4 1/2" x 1 1/4"  (1 pc.) ...........248
12b ........Firebrick - 3" x 4 1/2" x 1 1/4"  (1 pc.) .................247
12c ........Firebrick - 4" x 4 1/2" x 1 1/4"  (1 pc.) .................246

All parts may be ordered from your nearest Pacific Energy dealer.  
Contact Pacific Energy for the location of the dealer nearest you.

12d ........Firebrick - 7 1/4" x 4 1/2" x 1 1/4"  (1 pc.) ...........245
12e ........Firebrick - 9" x 4 1/2" x 1 1/4"  (17 pc.) ........5096.99
..............Firebrick Set ....................................... BRIC.SSERA
13a ........Brick Rail, Left (Latch Side) ............ SSER.RAILSET
13b ........Brick Rail, Right (Hinge Side)
..............Replacement Baffle Kit ..................... SSER.DBAKIT
14a ........Baffle (not sold separately) .................. SSER.DBAF
14b ........Side Insulation (not sold separately) ..... 5068.732.B
15 ..........Baffle Pin ............................................................125
16 ..........Baffle Gasket ...................................................139.5
17 ..........Flame Shield  (c/w Bolt and Nut) ............SSER.4115
18 ..........Air Shutter Assembly ............................WODC.4531
19 ..........Baffle Air Control Assembly ..................... SSER.214
20..........Ash Dump Assembly ............................WODC.2261
21..........Ash Box ................................................. FSND.4615
22............Ashlip...................................................
ALIP.5037473MB

Summary of Contents for STEP D1

Page 1: ...tions Contact local building or fire officials about restrictions and installation inspection requirements in you area 090709 16 STEP D1 5055 2012 TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets t...

Page 2: ...to follow instructions may result in property damage bodily injury or even death Contents Safety and Maintenance 3 Creosote 4 Formation and Need for Removal 4 Chimney Fires 4 In Case of a Chimney Fire...

Page 3: ...aintained in good condition Periodically inspect seals and replace if necessary Follow instructions included in the DR31 WDGKIT kit obtainable from your nearest Pacific Energy dealer 5 DOORGLASS Donot...

Page 4: ...solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Ch...

Page 5: ...090709 16 5 Stove Dimensions Double Wall Connector Mobile Home Alcove Min Height 7 1 2 Max Depth 4 Double Wall Connector Residential Single Wall Connector Residential Minimum Clearance to Combustible...

Page 6: ...t be installed with listed double wall con nector and compatible chimney system listed on page 7 Clearances to combustible surfaces and materials are shown in Figure 1 page 5 and Figure 2 page 7 Clear...

Page 7: ...tra Black 4 Selkirk Metalbestos Model DS 8 Simpson Dura Vent Model DVL B As well as one of the following compatible chimney systems All parts 6 CANADA ONLY Security Pro Jet ICC Selkirk Energy Vent S21...

Page 8: ...let for optimal performance Reducing or increasing the flue size may adversely affect stove performance Chimney flue exit is to be 3 feet 1 m above roof and two feet 0 6 m above highest projection wit...

Page 9: ...dislodging of the air duct Outside air may also be ducted from outside throughthe4 diameterholeintherearofthepedestal enclosure Note This unit is not designed to be operated with the firing door open...

Page 10: ...tove must be baked on with small fires When burning your stove for the first 2 3 times it is very important that the room be well ventilated Open all windows and doors Smoke and fumes caused by the cu...

Page 11: ...side pieces of insulation must be tight against the siderails WARNING Do not use grates or andirons to elevate the fuel Burn directly on the fire bricks Replace broken or missing bricks Failure to do...

Page 12: ...ear shield 7 Plug the power supply cord in and check blower operation Blower Operation Proper blower speed matched with air control setting will ensure peak performance from your stove Operate as foll...

Page 13: ...cessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Over...

Page 14: ...brick 3 x 4 1 2 x 1 1 4 1 pc 247 12c Firebrick 4 x 4 1 2 x 1 1 4 1 pc 246 All parts may be ordered from your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer nearest...

Page 15: ...STEP D1 090709 16 15 Label...

Page 16: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net...

Reviews: