Replacement Parts - Super 27

(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM 

DESCRIPTION 

PART NO. 

ITEM  DESCRIPTION 

PART NO.

1............ Side Shield, Left or Right.................... SUPD.4302
2............ Rear Defl ector ...................................... SSER.229
3............ Door Catch ........................................ WODC.1461
4............ Ash Lip  (c/w Trim & Hardware) .. ALIP.5037473MB
5............ Glass Clamps  (4 pc.) ......................... SSER.1425
6............ Glass Bar Set  (2 pc.) ...................... WODC.41405
7............ Replacement Glass  (c/w Tape) .....DR31.WGLKIT
8............ Door Gasket Kit ............................. DR31.WDGKIT
9............ Door Casting, Arched Black ................CAST.31ST
.............. Door Casting, Radiant Black ..........CAST.31RSST
.............. Door Casting, Arched Gold .................CAST.31GD
.............. Door Casting, Radiant Gold ..........CAST.31RSGD
.............. Door Casting, Arched Nickel.................CAST.31NI
.............. Door Casting, Radiant Nickel ..........CAST.31RSNI
10 .......... Door  Handle  Assembly ................... WODC.4147C
11 .......... Boost  Manifold  .............................................. 4105
12 .......... Firebrick  Set  .................................... BRIC.SSERA
13a ........ Brick Rail, Left/Right .................... SSER.RAILSET
14 .......... Replacement Baffle Kit .................. SSER.DBAKIT
15 .......... Baffle  Pin .........................................SSER.125001
16 .......... Baffle  Gasket ...................................... SSER.1395
17 .......... Flame Shield  (c/w Bolt and Nut) .........SSER.4115
18 .......... Pedestal Front Cover .......................... SSER.2075
19 .......... Pedestal  Assembly  .............................. SUPD.PED

All parts may be ordered from your nearest Pacifi c Energy 
dealer.  Contact Pacifi c Energy for the location of the dealer 

20.......... Ash System (Leg Model) ................ SUPD.LGADA
21.......... Leg, Black.........................................CAST.LEGST
.............. Leg, Gold Plated............................CAST.LEGGLD
.............. Leg, Nickel Plated ............................ CAST.LEGNI
24.......... Ash Dump Assembly .........................WODC.2261
25.......... Ash Box  (Pedestal Model) ................ WODC.4316
26.......... Air Shutter Assembly .........................WODC.4531
27.......... Baffle Air Control Assembly .................. SSER.214

24 

25 

11 

20 

18 

21 

19 

28 

28 

10 

10 

26 

27 

17 

13a 

13b 

14

14

12

14

15 

16 

20

20

Summary of Contents for SUPER 27 SPECTRUM

Page 1: ...nstalled a house fire may result For your safety followtheinstallationinstructions Contact local building or fire officials about restrictions and installation inspection requirements in your area IMP...

Page 2: ...nual before you install and use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Contents Safety and Maintenance 3 Maintenance Checks 4 Cre...

Page 3: ...es only light pressure to seal This will prolong seal life It is important that the door seal be maintained in good condition Periodically inspect seals and replace if necessary Follow instructions in...

Page 4: ...ng the Chimney System Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a...

Page 5: ...ary a certain amount of creosote is inevitable and must be lived with Regular inspection and clean ing is the solution The use of dry seasoned wood and ample combustion air will help to minimize the b...

Page 6: ...refully on its back 5 Using two 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom Optional Ash Cleanout System Install first 1 With stove body...

Page 7: ...G TESTED TO AS NZS 4013 ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHOR ITY IS CONSIDEREDTO BE IN BREACH OFTHEAPPROVAL GRANTED FOR COMPLIANCE WITH AS NZS...

Page 8: ...combustiblefloorprovidedember protectionmadefroma6mmthicknon combustiblematerialwith a thermal conductivity value of 4w m degree K This protection must extend as follows 300 mm on the firing side and...

Page 9: ...a chimney flue serving another appliance Minimum system height is 4600mm measured from base of appliance Installation Procedure 1 Install all components to the chimney manufacturer s installation requ...

Page 10: ...as 3 various cut size bricks If your heater came with an ash cleanout system or an optional one is being installed discard the extra full brick With the heater in the upright position install firebric...

Page 11: ...stallation requires the unit to be secured to the structure to prevent dislodging of the air duct To draw outside air from behind the stove cut or drill a 100mm hole through a wall behind the unit Use...

Page 12: ...on monoxide a taste less odourless gas that can kill Under no circumstances should you attempt to barbecue in this heater How to Test Your Wood Add a large piece of wood to the stove when it has a goo...

Page 13: ...approximately 25mm deep on the firebox bottom to help maintain a hot charcoal bed Optional ash cleanout system The ash dump han dle is located under the ash lip on the left hand side To operate ash d...

Page 14: ...latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t B...

Page 15: ...ant Nickel CAST 31RSNI 10 Door Handle Assembly WODC 4147C 11 Boost Manifold 4105 12 Firebrick Set BRIC SSERA 13a Brick Rail Left Right SSER RAILSET 14 Replacement Baffle Kit SSER DBAKIT 15 Baffle Pin...

Page 16: ...kel CAST 31NI Door Casting Radiant Nickel CAST 31RSNI 12 Door Handle Assembly WODC 4147C 13 Boost Manifold 4105 14 Firebrick Set BRIC SSERA 15a Brick Rail Left Right SSER RAILSET 16 Replacement Baffle...

Page 17: ...rstanding the basic functions of this design Traditionalwoodstoveshadabasiccombustion systemwhichallowedaconsiderableamountof heat energy to escape up the chimney as un burned gases and particulates s...

Page 18: ...18 SUPER SD1 230514 20...

Page 19: ...ARDWOOD 10 0 kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 67 WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 ALLENBY RD DUNCAN BC V9L 6V8 Tested by HRL TECHNOLO...

Page 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada...

Reviews: