background image

201213-20 

                                                                                                                        19

Label

 A. 
 14 IN. / 356 MM 

14 IN. / 356 MM

 B.  
15 IN. / 381 MM 

<

 13 IN. / 330 MM

 C.  
10 IN. / 254 MM 

10 IN. / 254 MM

 D.  
23 IN. / 585 MM 

23 IN. / 585 MM

 E.  
18 IN. / 457 MM 

<

 16 IN. / 406 MM

 F.

  19 IN. / 483 MM 

19 IN. / 483 MM

 A. 
 12 IN. / 305 MM 

12 IN. / 305 MM

 B.  
7 IN. / 178 MM 

 7 IN. / 178 MM

 C.  
3 IN. / 76 MM 

3 IN. / 76 MM

 D.  
20.5 IN. / 521 MM 

20.5 IN. / 521 MM

 E.  
9.5 IN. / 241 MM 

 9.5 IN. / 241 MM

 F.

  1

1.5 IN. / 292 MM 

11

.5 IN. / 292 MM

 A. 
 12 IN. / 305 MM 

12 IN. / 305 MM

 B.  
11

 IN. / 279 MM 

12 IN. / 305 MM

 C.   

N/A
 

8 IN. / 203 MM

 D.  
20.5 IN. / 521 MM 

20.5 IN. / 521 MM

 E. 
13.5 IN. / 343 MM 

14.5 IN. / 370 MM

 F

.   

N/A
 

16.5 IN. / 419 MM

CERTIFIED FOR CANADA

 AND U.S.A. 

 - SERIES / SÉRIE: 

C

   MODEL

 / MODÈLE: 

VIST

A

 

CLASSIC 

 P

ACIFIC VIST

A

   

 

ALDERLEA

 T4   

 

T4 CLASSIC   

LISTED ROOM HEA

T

ER, SOLID FUEL

 TYPE.

ALSO FOR USE IN MOBILE HOMES

TESTED T

O/ ÉPROUVÉ SELON: CAN/ULC S627-00 

AND UL

 1482-201

• 
INST

ALL

 AND USE IN 

ACCORDANCE WITH THE MANUF

ACTURER’S INST

ALLA

TION 

AND OPERA

TING 

 INSTRUCTIONS.

• 
CONT

ACT LOCAL

 BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS, INST

ALLA

TION PERMIT 

AND 

 INSPECTION 

IN 
YOUR 

AREA.

• 
DO NOT CONNECT THIS UNIT T

O

 A

 CHIMNEY

 FLUE SER

VING 

ANOTHER 

APPLIANCE (USA. ONL

Y).

• 
USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECT

OR.

• 
CAN BE CONNECTED T

O

 A

 LINED MASONR

Y

 CHIMNEY

 SUIT

ABLE FOR USE WITH SOLID FUELS.

• 
DO NOT OBSTRUCT THE SP

ACE BENEA

T

H THE HEA

T

ER.

• 
SEE LOCAL

 BUILDING CODE 

AND MANUF

ACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED 

WHEN P

A

SSING 

A

 CHIMNEY

 THROUGH 

A

 COMBUSTIBLE W

A

LL
 OR CEILING.

• 
DO NOT P

A

SS 
A

 CHIMNEY

 CONNECT

OR THROUGH 

A

 COMBUSTIBLE W

A

LL
 OR CEILING.

• 
MINIMUM CLEARANCE BETWEEN SINGLE W

A

LL
 CHIMNEY

 CONNECT

OR 

AND COMBUSTIBLE MA

TERI-

ALS-18INCHES/455MM.  CLEARANCE MA

Y

 BE REDUCED BY

 THE USE OF LISTED PIPE SHIELDS, W

A

LL
 

PROTECT

ORS OR OTHER MEANS 

APPROVED BY

 LOCAL

 BUILDING OR FIRE OFFICIALS.

• 
COMPONENTS REQUIRED FOR MOBILE HOME 

AND 

ALCOVE INST

ALLA

TION: OUTSIDE 

AIR KIT

.

 
BOTH CHIMNEY

 SYSTEM 

AND CONNECT

OR MUST BE LISTED T

O

:

 
IN CANADA

 -  ULC S-641 LISTED CONNECT

OR 

AND ULC-S-629 LISTED CHIMNEY

 
IN CANADA

 -  ULC S-641 LISTED CONNECT

OR 

AND ULC-S-629 LISTED CHIMNEY

 
IN USA

 -  UL-103 HT LISTED CONNECT

OR 

AND CHIMNEY

 
IN USA

 -  UL-103 HT LISTED CONNECT

OR 

AND CHIMNEY

 

• 
USE COMPONENTS SPECIFIED IN P

ACIFIC ENERGY

 INST

ALLA

TION INSTRUCTIONS.

• 
APPLIANCE MUST BE INST

ALLED WITH PEDEST

AL
 OR LEG KIT 

A

T

TACHED.

• 
OPTIONAL

 COMPONENTS - F

AN KIT

, F

AN ELECTRICAL

 RA
TING: 1

1

5V
, 60HZ, 1.0 

AMP

.

 
DO NOT ROUTE POWER CORD BENEA

T

H HEA

T

ER.

• 
CAUTION: RISK OF EXCESSIVE TEMPERA

T

URES - KEEP

 ASH DUMP

 CLOSED DURING FIRING OF THE 

HEA

T

ER.

• 
OPERA

T

E ONL

Y

 WITH FEED DOOR CLOSED.  OPEN T

O

 FEED FIRE ONL

Y

.

• 
KEEP

 FURNISHINGS 

AND OTHER COMBUSTIBLE MA

TERIALS WELL

 A

W

A

Y

 FROM HEA

T

ER.

• 
REPLACE GLASS ONL

Y

 WITH CERAMIC GLASS.

 
HORIZONT

A

L

 CONNECT

OR NOT PERMITTED IN MOBILE HOMES

 
AS TESTED - PIPE SHIELD MA

Y

 BE REQUIRED BY

 LOCAL

 AUTHORITIES.


COMBUSTIBLE 

ALCOVE SIZE : DEPTH - 3 FT

. / .91 M MAX., HEIGHT 7 FT

. / 2.1 M MIN., WIDTH 4 FT

. / 1.2 M 

MIN.

 
COMBUSTIBLE FLOOR MUST BE PROTECTED BY

 A

 CONTINUOUS NON-COMBUSTIBLE MA

TERIAL

 EX-

TENDED T

O

 THE FRONT

, SIDES 

AND BACK 

AS INDICA

TED.

MINIMUM CLEARANCES T

O

 

COMBUSTIBLE MA

TERIALS/

DÉGAGEMENTS MINIMALES 

AUX 

MA
TÉRIAUX COMBUSTIBLES

DO NOT

 REMOVE 

THIS LABEL

 

RACCORD

 

VERTICAL

 CONNECT

OR      

RACCORD

 

HORIZONT

A

L CONNECT

OR 

 

RESIDENTIAL

 CLOSE CLEARANCE INST

ALLA

TION 

USING DOUBLE W

A

LL

 CONNECT

OR/ 

INST

ALLA

TION 

RÉSIDENTIELLE 

AVEC DÉGAGEMENT MINIMAL, UTILISANT 

UN RACCORD DE MUR DOUBLE

* ALCOVE 

INST

ALLA

TION

USING DOUBLE W

A

LL

 

CONNECT

OR/
* INST

ALLA

TION 

EN 
ALCÔVE UTILISANT UN 

RACCORD DE MUR DOUBLE

WH-

RESIDENTIAL

 INST

ALLA

TION 

USING SINGLE W

A

LL
 CONNECT

OR/

INST

ALLA

TION RÉSIDENTIELLE UTILISANT UN 

RACCORD DE MUR SIMPLE

 IN CANADA

 

G. 

18 INCHES / 455 MM

 AU 
CANADA

 

H. 

8 INCHES / 200 MM

 

I. 

8 INCHES / 200 MM

 IN U.S.A. 

G. 

16 INCHES / 405 MM

 AUX 

ÉT

AT

S-UNIS

 H. 

4 INCHES / 102 MM

 

I. 

0 INCHES / 0 MM

MOBILE 

HOME INST

ALLA

TION

USING DOUBLE W

A

LL

 

CONNECT

OR/ 

INST

ALLA

TION 

EN MAISON MOBILE UTILISANT 

UN RACCORD DE MUR DOUBLE

 

WN#16405        ETL#4001507

• 

INST

ALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INST

ALLA

TION ET D’OPÉRA

TION FOURNI 

AVEC L

’APP
AREIL..

• 

CONT

ACTEZ LES OFFICIELS DE LA

 CONSTRUCTION OU DE SER

VICE D’INCENDIE POUR DES INFORMA

TIONS QUANT 

AUX 

RESTRICTIONS. PERMIS D’INST

ALLA

TION ET INSPECTIONS DANS VOTRE RÉGION.

• 

NE RELIEZ P

A

S CET 

APP

AREIL

 À UN CONDUIT DE CHEMINÉE DESSER

VANT DÉJÀ UN 

AUTRE 

APP

AREIL

 (ÉT
AT

S-UNIS SEULE-

MENT).

• 

UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET 

AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.

• 

PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE 

ALIGNÉE PRÊTE À L

’EMPLOI 

AVEC DES COMBUSTIBLES SOLIDES.

• 

DO NOT OBSTRUCT THE SP

ACE BENEA

TH THE HEA

TER / 

• 

CONSUL

TEZ LE CODE LOCAL

 DE CONSTRUCTION ET LES INSTRUCTIONS DU F

ABRICANT QUANT 

AUX PRÉCAUTIONS À 

PRENDRE LORSQUE VOUS F

A

ITES P

A

SSER UNE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MA

TÉ-

RIAUX COMBUSTIBLES.

• 

NE F

A

ITES P

A

S P
A

SSER UN RACCORDEMENT DE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MA

TÉ-

RIAUX 

• 

DÉGAGEMENT MINIMAL

 ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET T

O

UT MA

TÉRIEL

 COMBUSTIBLE - 18 

POUCES / 455 mm.  CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUY

AUX CLASSÉS, PROTEC-

TEURS DE MUR OU 

AUTRES MOYENS 

APPROUVÉS P

A

R LES OFFICIELS DE LA

 CONSTRUCTION OU DU SER

VICE D’INCENDIE 

DE VOTRE RÉGION.

 
CONNECTEUR HORIZONT

AL
 NON PERMIS DANS MAISONS MOBILES

• 
L

’APP

ARIEL

 DOIT COMPORTER UN ENSEMBLE POUR PIEDST

ABLE OU SUR P

A

TTES.

• 
PIÈCES REQUISES POUR INST

ALLA

TION EN MAISON MOBILE OU EN 

ALCÔVE:  NÉCESSAIRE D’APPROVI-

SIONNEMENT D’AIR EXTÉRIEUR ET L

’UN DES RACCORDS SUIV

ANTS:  EN COMBINAISON 

A

VEC L

’UN DES 

SYSTÈMES DE CHEMINÉE COMP

A

TIBLES SUIV

ANTS: 

 AU CANADA

 - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE

• 

 PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE:  1

15V
, 60HZ, 1.0 

AMP

.  LE FIL

 

ÉLECTRIQUE NE DOIT P

A

S ÊTRE PLACÉ SOUS LE POÈTE.

 

LE FIL

 ÉLECTRIQUE NE DOIT P

A

S ÊTRE PLACÉ SOUS LE POÊLE

• 

AT

TENTION:  RISQUE DE TEMPÉRA

TURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L

’ALLUMAGE DU 

POÈTE.

• 

OPÉREZ SEULEMENT LORSQUE LA

 PORTE D’ALIMENT

ATION EST FERMÉE.  

• 

OUVREZ SEULEMENT POUR 

ALIMENTER LE FEU.

• 

GARDEZ LES MEUBLES ET 

AUTRES MA

TÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.

• 

REMPLACES LA

 VITRE 

AVEC UNIQUEMENT DE LA

 VITRE CÉRAMIQUE.

 CONNECTEUR HORIZONT

A

L

 NON PERMIS DANS MAISONS MOBILES

TEL

 QUO ÉPROUVÉ UN PROTECTEUR DE TUY

AU PEUT ÊTRE REQUIS P

AR LES 

AUT

ORITÉS LOCALES

 * 

DIMENSION D’ALCOVE COMBUSTIBLE:  PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M MINI-

MUM.

 

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ P

A

R UN MA

TÉRIEL

 NON-COMBUSTIBLE T

O

UT D’UNE PIÈCE QUI DOIT 

S’ÉTENDRE DE P

AR LE DEV

ANT
, LES COTÉS ET L

’ARRIÈRE TEL

 QU’INDIQUÉ.

A. 
SIDEW

A

LL

 T

O

 UNIT/

 
MUR DE CÔTE / 

APP
AREIL

B. 
BACKW

ALL

 T

O

 UNIT/

M

UR DE FOND / 

APP
AREIL

C. 
CORNER T

O

 UNIT/

COIN / 

APP
AREIL

D. 
SIDEW

A

LL

 T

O

 CONNECT

OR/

MUR DE CÔTE / RACCORD

E. 
BACKW

ALL

 T

O

 CONNECT

OR/

MUR DE FOND / RACCORD

F. 

CORNER T

O

 CONNECT

OR/

COIN / RACCORD

BACK  I

HEA

T

ER

G

SIDE

H

FRONT

SIDE

H

COTE

COTE

DEV

A

NT

POELE

DOS

 

RACCORD

 

VERTICAL

 CONNECT

OR      

RACCORD

 

HORIZONT

AL
 CONNECT

OR 

 

MADE IN CANADA/ 

FABRIQUÉ AU 

CANADA


 F 

 M 

 A

 

 M 

 J 

 J 

 A

 

 S 

 O 


 D

2012 

2013 2014 2015 

2016 

2017

DA
TE OF MANUF

ACTURE/ 

DA
TE DE MANUF

ACTURE

VST1-C-1a

U.S. ENVIRONMENT

A

L

 PROTECTION 

AGENCY

 CERTIFIED T

O

 COMPL

Y

 WITH JUL

Y

1990, P

ARTICULA

T

E EMISSION ST

ANDARDS// 

CERTIFIÉ P

AR L

’AGENCE DE PROTECTION DE 

L’ENVIRONNEMENT DES ÉT

AT

S-UNIS (EP

A) EN 

ACCORD 

AVEC LES ST

ANDARDS D’ÉMISSION DE 

PARTICULES DE JUILLET 1990

5050.73

051
11

2

MANUF

ACTURED BY/ 

FABRIQUÉ P

AR:

P

ACIFIC ENERGY

 FIREPLACE PRODUCTS L

T

D.

2975 

ALLENBY

 RD., DUNCAN, BC  V9L

 6V8

HOT WHILE IN OPERA

TION.  DO NOT T

O

UCH.  KEEP

 CHILDREN, CLOTHING 

AND FURNITURE 

A

W

A

Y

.  CONT

ACT MA

Y

 CAUSE SKIN BURNS.  SEE NAMEPLA

T

AND INSTRUCTIONS.// 

CHAUD LORSQU’EN OPÉRA

TION.  NE P

A

S T
O

UCHER, TENEZ LES 

ENF
ANTS ET LES VÊTEMENTS BIEN À L

’ÉCART

.  LE CONT

ACT PEUT CAUSER DES BRÛLURES 

À LA

 PEAU.  CONSUL

TEZ LA

 PLAQUE CE CONSTRUCTEUR ET LES INSTRUCTIONS.

CAUTION

ADJACENT

 W
A

LL

BACK W

A

LL

D

A

SIDE WALL

B

E

ADJACENT WALL

F

C

MUR COTE

MUR ARRIERE

MUR ADJACENT

MUR ADJACENT

Summary of Contents for VISTA

Page 1: ...e fire may result For your safety followtheinstallationinstructions Contact local building or fire officials about restrictions and installation inspection requirements in your area IMPORTANT THESE IN...

Page 2: ...ion and Need for Removal 5 Chimney Fires 5 In Case of a Chimney Fire 5 Avoiding a Chimney Fire 5 Assembly 6 Crate Removal 6 Pedestal Kit 6 Leg Kit 6 Optional Ash Cleanout System 6 Mobile Home Installa...

Page 3: ...liquid to start a fire Do not burn garbage or flammable fluids such as gasoline naphtha or engine oil We strongly recommend that smoke detectors be installed 2 Remove ashes frequently Embers can roll...

Page 4: ...imney System Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacumn o...

Page 5: ...lived with Regular inspection and clean ing is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creosote build...

Page 6: ...he unit on its back and removable cover of the ash drawer enclosure facing up align mounting holes with studs on stove bottom 2 Position the legs on the stove 3 Place the 1 2 washers over the studs an...

Page 7: ...ashing Storm collar Hooded vent Attachment to floor for mobile homes Spark arrestor rain cap FIG 2 7 2 1 m Minimum Ceiling Height 58 1473 mm Minimum 48 1219 mm Minimum The chimney may incorporate an o...

Page 8: ...e flashing and storm collar and be sure to maintain the vapour barrier at this point Seal securely Attach rain cap and check flashing for leaks 6 Install connector as per manufacturer s instructions 7...

Page 9: ...ll connector for use with solid fuel Install all components to the chimney connector manu facturer s installation requirements Single wall Connector Smoke Pipe Smoke pipe must be secured at every join...

Page 10: ...osure to the floor with a short 4 diameter pipe If you wish to connect the outside air to the rear hole on the ash box then remove the 4 knockout or cover plate at the rear of the ash box Thisholemust...

Page 11: ...best finish the paint on your stove must be baked on When burning your stove for the first 2 3 times it is very important that the room be well ventilated Open all windows and doors Smoke and fumes c...

Page 12: ...out 1 2 and turn clockwise This will unlock the ash dump and allow it to open Hold handle openwhilepullingashesintothehole Avoidlargecharcoal pieces as these still contain heat value Release handle a...

Page 13: ...o and set the speed control to desired setting This will al low the fan to turn on as the stove heats up to operating temperature It will also shut the blower off after the fire has gone out and the u...

Page 14: ...air for combustion 4 Door gasket leakage Replace gasket Check latch EXCESSIVE CREOSOTE BUILDUP See 1 2 3 above LOW HEAT OUTPUT 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft...

Page 15: ...Door casting Brushed NIkel CAST 16BNI 10 Door handle assembly WODC 4147C 11 Firebrick set BRIC VISTA 12 Brick rail set VIST RAILSET 13 Rail extensions 2 pc VIST RAILEXT 14 Baffle kit VIST BAFKIT 15 F...

Page 16: ...4147C 11 Firebrick set BRIC VISTA 12 Brick rail set VIST RAILSET 13 Rail extensions 2 pc VIST RAILEXT 14 Baffle kit VIST BAFKIT 15 Flame shield c w nut bolt VIST 2115 16 Air shutter assembly VIST 453...

Page 17: ...g the basic functions of this design Traditionalwoodstoveshadabasiccombustion systemwhichallowedaconsiderableamountof heat energy to escape up the chimney as un burned gases and particulates smoke Pac...

Page 18: ...the upright position install firebricks as follows First install 4 full size firebricks against the rear wall Next install the side firebricks 2 full size each side Lastly place 4 full size on the bo...

Page 19: ...7 INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D INSTALLATION ET D OP RATION FOURNI AVEC L APPAREIL CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX...

Page 20: ...20 201213 20 Printed in Canada PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 6V8 Phone 250 748 1184 Web site www pacificenergy net...

Reviews: