- 5 -
NEVER:
•
Add acid to a battery.
•
Smoke near batteries.
•
Charge a frozen battery.
•
Leave an acid spill unattended.
•
Store batteries unless they are fully charged.
•
Charge a battery when the temperature is above 122°F (50°C).
•
Charge a flooded battery without securing vent caps on the cells.
•
Place objects on top of batteries, which can cause a short circuit.
SERVICING LEAD ACID BATTERIES (NON-HYDROLINK
®
MODELS)
REQUIRED EQUIPMENT
SAFETY
WATERING
CLEANING & INSPECTION
•
Eye protection
•
Acid resistant gloves
•
Distilled water
•
Baking soda to neutralize acid spills
ALWAYS:
•
Neutralize acid spills with baking soda and water.
•
Use insulated tools to verify connections are tight.
•
If contact with electrolyte (sulfuric acid) occurs, flush with large amounts of water.
•
Use only distilled water (tap water can contain contaminants that will damage the
battery).
•
Remove the caps and place them upside down to check electrolyte levels.
•
For discharged or partially charged batteries, add just enough water to cover the
plates.
•
Fully charge the batteries.
•
Add distilled water to a level of 1/8” (0.125”) below the vent well.
•
Fluid on the top of a battery may mean it is being over-watered or overcharged.
•
Check cleanliness and keep terminals and connectors free of corrosion.
•
Clean with a solution of one cup baking soda to one gallon of water.
•
Do not allow cleaning solution to get inside the battery.
•
Rinse with water and dry with a clean cloth.
•
Keep the area around batteries clean and dry.
•
Properly secure all vent caps.
•
Check battery cables and connections. Replace any damaged cables and tighten any loose connections.
Summary of Contents for RS28
Page 23: ...20 RETURN TO TABLE OF CONTENTS PAGE INTENTIONALLY LEFT BLANK...
Page 43: ...RETURN TO TABLE OF CONTENTS 40 PAGE INTENTIONALLY LEFT BLANK...
Page 52: ...49 RETURN TO TABLE OF CONTENTS ELECTRICAL DIAGRAMS...
Page 53: ...RETURN TO TABLE OF CONTENTS 50 ELECTRICAL DIAGRAMS...
Page 54: ...RETURN TO TABLE OF CONTENTS 51 DATE MAINTENANCE LOG...
Page 55: ...52 RETURN TO TABLE OF CONTENTS DATE MAINTENANCE LOG...
Page 57: ...54 RETURN TO TABLE OF CONTENTS PAGE INTENTIONALLY LEFT BLANK...
Page 58: ...www pacificfloorcare com...