- 6 -
SERVICING LEAD ACID BATTERIES WITH HYDROLINK
®
WATERING
SYSTEM
1. Position the container of distilled water below the level of the top of the batteries to prevent siphoning.
2. Place the end of the watering system hose in the distilled water and squeeze the bulb to fill the system.
3. Remove the dust cover from the Hydrolink
®
snake connected to the batteries.
4. Connect the coupler on the Hydrolink
®
snake to the coupler on the watering system using the quick disconnect fittings.
5. While squeezing the hand pump, observe the flow indicator (spinning red balls). As the batteries begin to fill, the spinning of the
flow indicator balls will slow. Batteries are full when the flow indicators completely stop spinning.
NOTE
: Battery systems may take more than 1/2 gallon of water once the BatteryShield
®
light has illuminated. Failure to actuate the
hand pump until the flow indicator stops spinning will result in batteries being under or unevenly serviced which will reduce
battery life.
6. When the flow indicator stops, and not before, disconnect the coupler by depressing the push button on the watering system
coupler.
NOTE
: Leaving the watering system connected could result in the batteries being over filled. Disconnecting the watering system
before the flow indicator stops spinning will result in batteries being under serviced and battery life will be reduced.
7. Replace the dust cover on the Hydrolink
®
snake.
BATTERYSHIELD
®
AUTOMATED WET BATTERY PROTECTION
SYSTEM
Machines equipped with BatteryShield
®
technology have a sensor installed on one of the battery caps and a red LED indicator located
on the Control Panel. This sensor monitors the water level in the batteries and the LED communicates to the operator that the batteries
require servicing. When the BatteryShield
®
LED is lit, the scrub head is disabled until battery servicing has been performed.
•
When the key switch is turned on, the BatteryShield
®
system will check the water level of the batteries.
•
If the LED turns off, there is sufficient water in the batteries.
•
If the LED remains on (without flashing), the batteries require servicing and the scrub head will not run.
•
If the LED flashes intermittently, the BatteryShield
®
light pipe must be cleaned (instructions below).
NOTE
: Failure to clean the BatteryShield
®
light pipe will limit the system’s ability to read the water level and will reduce battery life.
•
If the BatteryShield
®
LED indicates the need for servicing, turn off the key switch and service the batteries as described above.
•
After completing the Hydrolink
®
watering system procedure, turn the key switch back on and verify the LED turns off.
Summary of Contents for S-20
Page 5: ...PAGE INTENTIONALLY BLANK...
Page 25: ...20 RETURN TO TABLE OF CONTENTS PAGE INTENTIONALLY BLANK...
Page 29: ...RETURN TO TABLE OF CONTENTS 24 PAGE INTENTIONALLY BLANK...
Page 40: ...35 RETURN TO TABLE OF CONTENTS CONTROLS S 24XM TRACTION MODELS...
Page 42: ...37 RETURN TO TABLE OF CONTENTS S 20HD CONTROLS...
Page 50: ...45 RETURN TO TABLE OF CONTENTS S 20HD DISK SCRUB HEAD...
Page 61: ...RETURN TO TABLE OF CONTENTS 56 PAGE INTENTIONALLY BLANK...
Page 62: ...RETURN TO TABLE OF CONTENTS 57 DATE MAINTENANCE LOG...
Page 63: ...58 RETURN TO TABLE OF CONTENTS DATE MAINTENANCE LOG...
Page 66: ...www pacificfloorcare com...