4
Set at Sensor Activate (Sensor & Dry) function.
(Default)
Set at Auto Flow (Tear & Dry) function with 2 second
delay after every dispense.
PAPER FEED
-
Sensor or Auto Flow
To set Sensor Activate or Auto Flow (Tear & Dry)
function adjust DIP Switch
3
as follows:
Manual Feed Button
Dip Switches
To set the DIP switch:
Use a small screw driver
or a pen to flip the switch
up or down to the desire
setting.
CONNECT BATTERY BOX TO DISPENSER
2.
Slide the battery box behind the Gear box. Make sure the
back of the battery box is facing you.
1.
Load 4 x D
-
Cell Alkaline batteries into battery box.
Recommend using Energizer or Duracell alkaline LR
-
20
batteries.
3.
Plug the battery connector into the dispenser. The LED
indicator will flash
GREEN
/
RED
three times indicating
the unit has power.
1
2
3
Check batteries and battery box for corrosion.
If corroded, replace as follows: