Function button #1 (DIG_IN) selects the digital input data being monitored as the clock
source, button #3 (A/D_REF) selects the clock source selected in the A/D Reference Clock
Menu as the clock source.
The Monitor Reference Clock Menu is used to select the D/A converter clock source when
monitoring digital input signals while in AD operating modes. See page 26 for details.
External Ref Clock Frequency Menu
In 2X or 4X AD and DD operating modes, the External Ref Clock Frequency Menu is reached
from the Operating Menu by selecting (SETUP/INPUT/REF_FRQ).
Function buttons #1 (1X_REF) and #3 (2X_REF) select the frequency of the external refer-
ence clock source when REF_AES or REFWCLK are selected in the A/D Reference Clock Menu
and the frequency of the reference word clock output of the Model Two when MASTER is
selected in the A/D Reference Clock Menu. See NOTE on page 27.
Monitor Digital Input Format Menu
In 88.2 kHz (2_X) AD operating mode, the Monitor Digital Input Format Menu is reached
from the Operating Menu by selecting (SETUP/INPUT/FORMAT).
Function button #1 (1_WIRE) selects single wire, double speed AES as the digital input