SECTION 3 INSTALLATION
43
3.2
OUTPUT VOLTAGE RANGE CONFIGURATION
The AMX-Series Power Source can be configured for several different Output Voltage Ranges.
The standard output configurations are:
Transformer
Ratio
Voltage Range
Model
Direct
Coupled
-
0-135 VAC
l-n
Standard on most models.
-
0-150 VAC
l-n
112-AMX,125-AMX and 312-AMX
Transformer
Coupled
VR1.5
0-204 VAC
l-n
Models 105-AMXT, 108-AMXT, 140-AMXT,
160-AMXT, 305-AMXT, 308-AMXT, 320-AMXT,
345-AMXT, 360-AMXT, 390-AMXT and
3120-AMXT equipped with Magnetics Option.
VR2.0
0-273 VAC
l-n
Models 105-AMXT, 108-AMXT, 140-AMXT,
160-AMXT, 305-AMXT, 308-AMXT, 320-AMXT,
345-AMXT, 360-AMXT, 390-AMXT and
3120-AMXT equipped with Magnetics Option.
VR2.5
0-341 VAC
l-n
Models 105-AMXT, 108-AMXT, 140-AMXT,
160-AMXT, 305-AMXT, 308-AMXT, 320-AMXT,
345-AMXT, 360-AMXT, 390-AMXT and
3120-AMXT equipped with Magnetics Option.
The 0-135 through 0-150VAC output ranges are direct-coupled outputs and are always
available. Standard transformer output ratios are 1.5, 2.0 and 2.5 step-up ( custom ratios are
available on request). The output transformer tap will be configured at the factory as
specified. The system ID label or magnetic module ID label will state the factory set
transformer ratio. If a different ratio is required, re-connect the transformer wiring according
to the following diagrams. The ID label should be updated also.
Described in the following paragraphs are model specific controller details (Transformer Ratio
and Amps to Volts Ratio settings) that, although factory preset, must be set as described if
inadvertently changed or otherwise modified.
Configuration of the Output voltage consists of:
1) Verifying that the appropriate output transformer taps have been selected.
2) Verifying the proper setting of the Transformer Ratio Setting within the UPC.
3) Verifying the proper setting of the Amps to Volts Ratio Setting within the UPC
4) Calibration of the system.
Configuration varies from model to model. The following paragraphs describe the
configuration settings of the available standard output ranges. Refer to the appropriate
paragraph for details. When custom output transformers have been installed, refer to
Section 9, Modifications. Any instructions stated in Section 9 take precedence over those
listed in the following paragraphs.