LMX Series Power Source Operation Manual
Page 94 of 463
6.4.2
PROGRAM Output Parameters
Figure 6-2: PROGRAM Screen
The two data entry methods described apply to the parameters on the PROGRAM &
MEASUREMENTS screen. This includes those shown in the table below.
PARAMETER
Range
Unit
Description
Frequency
15 - 5000
1
Hz
Output frequency
Voltage AC
0 – 300
1
V rms
AC output
Current limit
0 to Max
A rms
RMS Current Limit
Power limit
0 to Max
W
True Power Limit
kVA limit
0 to Max
VA
Apparent Power Limit
Table 6-2: Available Output Parameters on PROGRAM screen
Note 1:
Range may differ for models with Transformer (T) Option.
Each screen has up to five soft keys on the right hand side of the display. These may change
as the selected parameter changes. To move between parameter fields in any screen, use
the shuttle knob. To change a parameter, press the shuttle knob and then adjust the value
by turning the shuttle. When done, press the shuttle to exit edit mode.