LMX Series Power Source Operation Manual
Page 247 of 463
Command Syntax
[SOURce:]INITial <n>
Description
Sets source output settings initialization mode. This command in
combination with the “OUTPut[:STATe]:AUTO” command allows the
unattended resumption of a test station after a power failure.
Note:
This condition is potentially hazardous and should be used
with caution.
[SOURce:]INITial? = ON Set points of the unit at power on will be the last set after power off.
The set points affected by this command are:
- Frequency
- Voltage AC1
- Voltage AC2
- Voltage AC3
- 0
- 0
- 0
- Form (THREE , SPLIT or SINGLE)
- Range (High or Low)
- Compatibility Mode (UPC or NORMAL)
[SOURce:]INITial? = OFF Set points of the unit at power on will have a default value of:
- Frequency = 60Hz
- Voltage AC1 = 0V
- Voltage AC2 = 0V
- Voltage AC3 = 0V
- 0
- 0
- 0
- Form = THREE
- Range = HIGH
- Compatibility = NORMAL
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
:INIT ON
Query Format
[SOURce:]INITial?
Returned Data Format
<b>
Query Example
INIT?
0