LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 315 of 463
8.9
System Commands
Systems commands control system level functions or return model and revision information
on the connected unit. The following system commands are supported.
8.9.1
System Error Commands
Query Format
SYSTem:ERRor[:NEXT]?
Description
This command returns next available error message from the error
queue. If no more error messages are available, returns 0,”NO ERROR”
result. Available error messages are:
Returned Data Format
ERROR
Description
-0, "No error"
No error detected
-100,"Command error"
indicates invalid command or query
received
-102,"Command error: Syntax
error.”
Incorrect command syntax
-200,"Execution error"
indicates can't execute command
with parameters received
-222,"Command error: Data
out of range.'
Data exceeds available parameter
range
-300,"Device-specific error"
indicates UPC not properly
configured
-400,"Query error"
indicates query aborted
Query Example
SYST:ERR?
-102,"Command error: Syntax error.”
Query Format
SYSTem:ERRor:ALL?
Description
Returns all available error messages as a of error numbers and clears
the error message queue.
Returned Data Format
<nr1>,<nr1>,…..<nr1>
Query Example
SYST:ERR:ALL?
-222,-201,0
Command Syntax
SYSTem:ERRor:ALL:CLEAR
Description
This command clears the error message queue.
Parameters
None
Parameter Format
n/a
Example
SYST:ERR:ALL:CLEAR
SYSTem:ERRor:ALL:NOCLEAR?
Description
Returns all available error messages as a single unterminated string
but does not clear
the error message queue.
Returned Data Format
<nr1>,<nr1>,…..<nr1>
Query Example
SYST:ERR:ALL:NOCLEAR?
2018/05/29,14:29:53,1207438.903668873,0,1,0