LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 339 of 463
Command Syntax
SYSTem:AIO:INput[n]:GAIN <nr2>
Description
Sets the full-scale gain of the LMX parameter controlled by the
analog input.
Parameters
Full scale value
Parameter Format
<nr2>
Example
SYST:AIO:IN1:GAIN 230.0
Query Format
SYSTem:AIO:INput[n]:GAIN?
Returned Data Format
<nr2>
Query Example
SYST:AIO:IN1:GAIN?
230.00
Query Format
SYSTem:AIO:INput[n]:GAIN:DEFault?
Description
Returns the default full-scale gain for the specified analog input.
Parameters
None
Returned Data Format
<nr2>
Query Example
SYST:AIO:IN1:GAIN:DEF?
300.0
Query Format
SYSTem:AIO:INput[n]:GAIN:MAXimum?
Description
Returns the maximum full-scale gain for the specified analog input.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:IN1:GAIN:MAX?
100000.000000
Query Format
SYSTem:AIO:INput[n]:GAIN:MINimum?
Description
Returns the minimum full-scale gain for the specified analog input.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:IN1:GAIN:MIN?
-100000.000000
Command Syntax
SYSTem:AIO:INput[n]:OFFSET <nr2>
Description
Sets the offset of the LMX parameter controlled by the analog input.
Parameters
Offset
Parameter Format
<nr2>
Example
SYST:AIO:IN1:OFFSET 50.0
Query Format
SYSTem:AIO:INput[n]:OFFSET?
Returned Data Format
<nr2>
Query Example
SYST:AIO:IN1:OFFSET?
15.00