8.12.2
Status Event Register (ESR)
Events reported by the STANDARD EVENT STATUS register may be queried via the *ESR?
command. Reading the ESR register clears it. The EVENT STATUS summary bit in the STATUS
BYTE (STB) will be set when an unmasked EVENT STATUS bit goes true.
BIT
NAME
DEFINITION
7
PON
POWER ON indicates Input power was just applied
6
URQ
USER REQUEST indicates "LOCAL" key was just pressed
5
CME
COMMAND ERROR indicates invalid command or query received
4
EXE
EXECUTION ERROR indicates can't execute command with data received
3
DDE
DEVICE DEPENDANT ERROR indicates UPC not properly configured
2
QYE
QUERY ERROR indicates cannot respond with data
1
RQC
REQUEST CONTROL - not used
0
OPC
OPERATION COMPLETE indicates previous operation complete
Table 8-5: Status Event Register (ESR)
Setting an EVENT STATUS ENABLE (ESE) bit true unmasks the EVENT bit in the ESR. Also see
:SYSTem:ERRor? query for relevant information.
Figure 8-3: Standard Event Register (ESR) Model