Error Source
Code
Category Error Message
Possible Cause
Resolution
programmed exceeds
max peak voltage
Front panel
122
Error
Cannot load program.
Run PROG:CHECK? for
more information.
Setting conflict
Use PROG:CHECK?
Command to query
conflict details
Front panel
125
Error
Remote inhibit cannot be
disabled in this model.
Remote Inhibit always
enabled. Unit was bought
with Output Control
Switch (OCS) option
which always enables
Remote Inhibit
Connect Remote Inhibit
input as needed.
Front panel
126
Error
Line to line
measurements only
available with sinewaves.
Measurement not
available. Line to Line
voltage measurements
can be calculated from L-
N and Phase Angles only
when all phase
waveforms are Sine
Set all phases to use SINE
waveform #1.
Front panel
127
Error
Digital I/O interface
conflict: Single-Phase
relay control is active.
Setting conflict
Front panel
128
Error
Digital I/O interface
conflict: Single-Phase
relay cannot change with
output enable.
Setting conflict. Changing
Phase mode only allowed
when Output is OFF
Turn Output OFF
Front panel
129
Error
Digital I/O interface
conflict: Single-Phase
relay cannot change due
relay closed.
Setting conflict
Front panel
131
Error
Cannot set EEPROM field.
Front panel
132
Error
EEPROM field already set.
Front panel
133
Error
Cannot read EEPROM
field.
Front panel
148
Error
Serial number mismatch:
Front panel does not
match power stages.
Setting conflict. Front
panel does not match
power stages serial
number
Contact customer service
Front panel
150
Error
Suffix not allowed in
single form.
Setting conflict.
Command suffix invalid
for Single Phase mode
Change phase mode
Front panel
151
Error
Suffix not allowed in split
form.
Setting conflict.
Command suffix invalid
for Split Phase mode
Change phase mode
Front panel
152
Error
Peak current limit setting
is too low for the desired
voltage and frequency.
Setting conflict. Peak
current limit setting too
low to support requested
voltage and frequency.
LMX has a minimum peak
limit because it affects
output inductor current
and at high frequencies, a
circulating current
proportional to the
voltage and frequency
occurs.
Increase the peak current
limit setting
Front panel
153
Error
Program transient trigger
input is disabled.
Setting conflict. External
Trigger Input disabled
Enable External Trigger
Input