LMX SERIES® OPERATION MANUAL
SECTION 4: Technical Specifications
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 48 of 463
4.11
Dimensions & Weight by Model
MODEL
HEIGHT
WIDTH
DEPTH
WEIGHT w/o & [w T]
105LMX
5.25” / 134 mm
19” / 483 mm
23” / 584 mm
70 lbs / 32 kg [97 lbs / 44 kg]
108LMX
5.25” / 134 mm
19” / 483 mm
23” / 584 mm
70 lbs / 32 kg [97 lbs / 44 kg]
112LMX
5.25” / 134 mm
19” / 483 mm
23” / 584 mm
80 lbs / 36 kg
140LMX
14” / 356 mm
19” / 483 mm
23.5” / 597 mm
185 lbs / 84 kg
160LMX
14” / 356 mm
19” / 483 mm
23.5” / 597 mm
195 lbs / 88 kg
305LMX
5.25” / 134 mm
19” / 483 mm
23” / 584 mm
74 lbs / 34 kg [100 lbs / 45 kg]
308LMX
5.25” / 134 mm
19” / 483 mm
23” / 584 mm
74 lbs / 34 kg [100 lbs / 45 kg]
312LMX
5.25” / 134 mm
19” / 483 mm
23” / 584 mm
80 lbs / 36 kg
320LMX
8.75” / 222 mm
19” / 483 mm
23.12”/587 mm
150 lbs / 68 kg
345LMX
14” / 356 mm
19” / 483 mm
23.5” / 597 mm
190 lbs / 86 kg
360LMX
14” / 356 mm
19” / 483 mm
23.5” / 597 mm
195 lbs / 88 kg
4.11.1
Rack Handles
The front panel mounted rack handles are intended for use in installing or removing the
power source from a 19” instrument cabinet only.
These handles should
not be used
to carry or move the power source to a different location.
Always use a suitable cart for lift to move the power source.
4.11.2
Rack Mount Slides
The chassis of the LMX-Series Power Source is designed to accept slide rails. These can be
provided as a cost option. For more information, contact your local sales representative or
the Pacific Power Source Sales Office.
Do not
install or remove the power source with less than two persons in view of the unit’s
weight. It is strongly recommended to use a suitable mechanical lift to install/remove the
unit in a cabinet.
4.12
Environmental
ENVIRONMENTAL
Cooling
Fan Cooled, Front and/or Side air intake, rear exhaust
Maximum Air flow by Model:
105LMX, 108LMX, 305LMX, 380LMX
100 CFM
112LMX, 312LMX
200 CFM
320LMX
300 CFM
140LMX, 160LMX, 345LMX, 360LMX
600 CFM
Operating Temperature
0 to 55 °C / 32 to131 °F
Storage Temperature
-20 to 70 °C / -4 to 158 °F
Humidity
< 95%, non-condensing
Altitude (max.)
2000 m / 6561 feet
7
Front panel width. Chassis width is 16.75” / 426 mm for models < 2.5kVA or 17” / 432 mm for 2.5kVA & higher models.
8
Measured from back side of front panel to front panel. Excludes terminal block depth.