ADF SERIES™ OPERATION MANUAL
Rear Panel, Connectors and Protection
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 153 of 349
7.3.9
User Programmable Digital signals
Available user defined digital input and outputs are provided as part of the I/O feature.
These signals may be assigned different purposes under software control.
DIGITAL
I/O
PLC
User Programmable Digital Input signals functions are:
•
DIO:INput1 - Digital Input #1
•
DIO:INput2 - Digital Input #2
•
DIO:INput3 - Digital Input #3
User Programmable Digital Output control signals are:
•
DIO:OUTput1 - Digital Output – TTL level
•
DIO:OUTput2 - Digital Output – TTL level
•
DIO:OUTput3 - Digital Output – Open drain
•
DIO:OUTput4 - Digital Output – Open drain
Digital outputs 3 and 4 are open drain with in5Vdc pull-ups.
7.3.9.1
Relay Control Outputs
RELAY
CONTROL
The external relay control output signals DO3 and DO4 can be used to control external
relays. These control lines are user programmable for difference functions such as FORM
relay control and Transformer Option control.
Summary of Contents for 1150ADF
Page 348: ......