ADF SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 198 of 349
Command Syntax
[SOURce:]RANGe
Description
Selects high or low voltage range. Although the ADF Series® has only
a single voltage range, this commands allows simulation of a dual
range AC voltage source which is more familiar to some users.
Despite this virual low range capability, no actual physical range
change takes places so the output is never interrupted.
Note: When switching from HIGH to LOW range, the output voltage
may be reduced to the highest available voltage on the low range.
Parameters
< 0 | LOW | 1 | HIGH >
Parameter Format
<b>
Example
RANG HIGH
Query Format
[SOURce:]RANGe?
Returned Data Format
<b>
Query Example
RANG?
1
Command Syntax
[SOURce:]RAMP#
Description
Sets voltage slew rate for selected phase number or for all phases if
no phase number is specified.
Parameters
Slew rate
Parameter Format
<nr2>
Example
SOUR:RAMP3 10.5
Query Format
[SOURce:]RAMP#?
Description
Returns voltage slew rate setting for specified phase (1, 2 or 3) or for
phase 1 (A) if no phase number is specified.
Returned Data Format
Query Example
SOUR:RAMP3?
10.5000
Command Syntax
[SOURce:]UPDATEPHase
Description
Set the phase angle at which programmed voltage changes on phase
A will take place. This applies to output on and off phase angle
placement as well. Available range is from 0° through 360.0°
inclusive. Values higher than 360.0° will be truncated to 360.0000°
automatically.
Parameters
< 0.0000 - 360.0000 >
Parameter Format
<nr2>
Example
UPDATEPH 90.00
Query Format
[SOURce:]UPDATEPHase?
Returned Data Format
<nr2>
Query Example
SOURce:UPDATEPH?
90.0000
Summary of Contents for 1150ADF
Page 348: ......