ADF SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 200 of 349
Command Syntax
[SOURce:]VOLTage[:AC]#:SLEW
Description
Sets AC voltage slew rate for phase # in Volts per msec. If # is
omitted, sets phase A slew rate to value specified.
Parameters
Range 0.01 – 300.0
Parameter Format
<nr2> and <nr3>
Example
VOLT:AC1:SLEW 300.00
Query Format
[SOURce:]VOLTage[:AC]#:SLEW?
Description
Returns voltage slew rate setting for specified phase. If phase is
omitted, returns voltage setting for phase A.
Returned Data Format
<nr2>
Query Example
VOLT:AC1:SLEW?
300.0000
Command Syntax
[SOURce:]VOLTage[:AC]:LIMit:MINimum
Description
Sets low user limit for AC voltage programming. User limits must fall
within actual hardware limits of the power source. Also, MIN limit
must be less than MAX limit.
Parameters
0.000 – 300.000
Parameter Format
<nr2>
Example
VOLT:LIM:MIN 20.0
Query Format
[SOURce:]VOLTage[:AC]#:LIMit:MINimum?
Returned Data Format
<nr2>
Query Example
VOLT:LIM:MIN?
20.0000
Command Syntax
[SOURce:]VOLTage[:AC]:LIMit:MAXimum
Description
Sets high user limit for AC voltage programming. User limits must fall
within actual hardware limits of the power source. Also, MAX limit
must be greater than MIN limit.
Parameters
0.000 – 300.000
Parameter Format
<nr2>
Example
VOLT:LIM:MAX 240.0
Query Format
[SOURce:]VOLTage[:AC]#:LIMit:MAXimum?
Returned Data Format
<nr2>
Query Example
VOLT:LIM:MAX?
240.0000
Query Format
[SOURce:]VOLTage[:AC]#:LIMit:RANGe?
Description
Returns available AC voltage range low and high limits.
Returned Data Format
<nr2>,<nr2>
Query Example
VOLT:AC1:LIM:RANG?
0.0000,300.0000
Summary of Contents for 1150ADF
Page 348: ......