Command Syntax
[SOURce:]VOLTage[:AC]:INITial
Description
This command is equivalent to the “[SOURce:]INITial <n>” command
but applies only to the AC1, AC2 and AC3 parameters.
VOLT:INIT? = ON Set points of the unit at power on will be the last set after power off.
The set points affected by this command are:
- Voltage AC1
- Voltage AC2
- Voltage AC3
VOLT:INIT? = OFF Set points of the unit at power on will have a default value of:
- Voltage AC1 = 0V
- Voltage AC2 = 0V
- Voltage AC3 = 0V
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
VOLT:AC:INIT OFF
Query Format
[SOURce:]VOLTage[:AC]:INITial?
Returned Data Format
<b>
Query Example
VOLT:AC:INIT?
0
Command Syntax
[SOURce:]VOLTage:EXTend
Description
Available only on ADF models with Option V.
This command grants access to a higher voltage range extension
mode. When enabled, AC voltage settings up to 333V L-N are
supported.
Parameters
[ 0 | OFF | 1 | 2 ]
0 = Off, 312Vac max.
1 = 320Vac max
2 = 333Vac max
Parameter Format
<bool>
Example
VOLT:EXT 1
Query Format
[SOURce:]VOLTage:EXTend?
Returned Data Format
<nr1>
Query Example
VOLT:EXT?
1
Commands available only with Option D:
Command Syntax
[SOURce:]VOLTage:DC#
Description
Sets DC voltage for phase #. If # is omitted, sets all available phases to
value specified.
Note:
Source must be in DC or AC+DC mode and UPC compatibility
mode must be disabled.
Parameters
Range 0.0000 - 425.0000
Parameter Format
<nr2>
Example
VOLT:DC1 375.0
Query Format
[SOURce:]VOLTage:DC#?
Returned Data Format
<nr2>
Query Example
VOLT:DC1?
375.0000