ADF SERIES® OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 26 of 349
AC OUTPUT
Note 4:
FREQUENCY PROGRAM RESOLUTION FOR EXPORT MODELS WITH OPTION E (-4GE, -2GE):
Per U.S.A. Bureau of Industry and Security, ECCN 3A225, frequency control is limited to no better than 0.2%
at frequencies of 600 Hz. or more for unrestricted export products. To meet that requirement, frequency
programming in all -2GE and -4GE ADF models has three resolution ranges, which round the frequency to
the nearest increment, as defined in the table below.
Frequency Resolution for Export Models
Range
Resolution
1.00 - 99.99 Hz
0.01 Hz
100-599.9 Hz
0.1 Hz
600 - 999 Hz
2.0 Hz
1000 - 1200 Hz
5.0 Hz
Note 5:
Refer to Voltage / Current ratings tables.
Note 6:
Actual output phase angles may be slightly different from programmed values for highly unbalanced three
phase load conditions, in particular at high frequency due to amplifier phase shift differences.
Figure 4-1: Output Voltage distortion into full R Load as a function of Frequency