ADF SERIES® OPERATION MANUAL
SECTION 5: UNPACKING AND INSTALLATION
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 41 of 349
5.3
Verify Correct AC Input Line Voltage
The ADF Series® power supply can be ordered with a range of 3 phase AC input voltage
configurations. Prior to connecting the AC power source to the local mains, it is important
to check the type label on the unit to verify that its AC input configuration matches the local
utility power.
Do not connect the power supply to the mains if the AC input voltage, phasing and
frequency does not match.
WARNING
DO NOT
CONNECT A 208 – 240 V AC INPUT ADF MODEL TO
A 380V, 400V OR 480V OR HIGHER THREE PHASE UTILITY
LINE VOLTAGE AS DAMAGE TO THE UNIT MAY OCCUR.
DO NOT
CONNECT A 380 – 480 V AC INPUT ADF MODEL TO
A 208V TO 240V THREE PHASE UTILITY LINE VOLTAGE AS
THE UNIT WILL NOT OPERATE.
AVERTISSEMENT
NE PAS
CONNECTER UNE 208-240 V AC ENTRÉE ADF
MODÈLE À UN 380V, 400V OU 480V OU PLUS DE TROIS
PHASES UTILITAIRE TENSION EN PANNE QUI PEUT SE
PRODUIRE.
NE PAS
CONNECTER UNE 380 - 480 V AC ENTRÉE ADF
MODÈLE À UN 208V TO 240V TRIPHASE UTILITAIRE
TENSION QUE L'APPAREIL NE FONCTIONNE PAS.
Summary of Contents for 1150ADF
Page 348: ......