ADF SERIES® OPERATION MANUAL
SECTION 5: UNPACKING AND INSTALLATION
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual
Page 68 of 349
5.15.5
Recommended AC Input Wire Strip Lengths
The following wire strip lengths are required for the AC input
wires listed.
L1, L2, L3 Wires:
11/16”, 17 mm
Neutral, Ground Wires:
3/4”, 19 mm
Connect AC input power three phase with correct Voltage to terminal block TB1 as shown in
the figure below.
The AC i phase terminals are oriented as shown below when facing the back of the cabinet.
CAUTION: Connect the Chassis Ground Stud to earth ground to ground the cabinet.
Cabinet must be grounded for safety purposes at all times.
N N øC øB øA L1 L2 L3
CHASSIS GROUND
CONNECTION
TB1 - AC INPUT POWER
THREE PHASE
TB2 - OUTPUT POWER
THREE PHASE
Figure 5-19: ADF Cabinet AC Input Connection Terminal Block TB1
5.15.6
Cabinet System AC Input Neutral
The ADF power sources DO NOT require a neutral connection as they operate from a Delta
AC input of either 208V L-L or 380 to 480V L-L. However, some available cabinet options
may operate from Line to Neutral input voltage only. If so, a neutral connection will be
present at the AC input side of the cabinet and this Neutral must be brought into the cabinet
(Wye). Refer to Section 5.17, “Cabinet System Options” for more details.