SECTION 1 GENERAL
4
1.3
GENERAL PRODUCT DESCRIPTION
The AMX-Series Power Source is high-performance AC power conversion equipment. This
series of equipment features models with power ratings from 500 VA to 30 kVA. All systems
are designed to fit into a standard 19 inch rack. These systems are suitable for use as
frequency changers as well as sophisticated test power generators.
All systems are configured with an interchangeable controller (UPC-Series). Controller
options range from basic manual control (UPC1M and 3M) to sophisticated programmable
controllers (UPC1, UPC3, UPC12 or UPC32). The manual controller allows the user to adjust
voltage and frequency. The programmable controller allows control of voltage and frequency,
and also allows the user to simulate virtually any transient (including sub-cycle waveform
disturbance) required for testing today's modern electronic equipment.
The standard output voltage range for most of the AMX-Series is 0-135 VAC
l-n
. Additionally,
the Models 112-AMX, 125-AMX and 312-AMX can operate from 0 to 150 VAC
l-n
. Optional
output transformers are available to provide higher voltages. Voltage ratios up to 2.5:1 are
readily available. Other transformer ratios are available by special order.
The AMX-Series consists of the basic models listed below:
1.
Model 105-AMX - 500 VA, capable of 1 or 2 Phase operation. Single phase output
voltage range is 0-135 VAC
l-n
. Output voltage in 2 Phase Mode is 0-270 VAC
L1-L2
.
Internal output transformer option available for higher voltages.
2.
Model 108-AMX - 750 VA, capable of 1 or 2 Phase operation. Single phase output
voltage range is 0-135 VAC
l-n
. Output voltage in 2 Phase Mode is 0-270 VAC
L1-L2
.
Internal output transformer option available for higher voltages.
3.
Model 112-AMX - 1.2 kVA, capable of 1 or 2 Phase operation. Single phase output
voltage range is 0-150 VAC
l-n
. Output voltage in 2 Phase Mode is 0-300 VAC
L1-L2
.
Additional ranges available with custom external transformer configurations.
4.
Model 125-AMX – 2.5 kVA, capable of 1 or 2 Phase operation. Single phase output
voltage range is 0-150 VAC
l-n
. Output voltage in 2 Phase Mode is 0-300 VAC
L1-L2
.
Additional ranges available with custom external transformer configurations.
5.
Model 140-AMX – 4.0 KVA, capable of 1 or 2 Phase operation. Single phase output
voltage range is 0-135 VAC
l-n
. Output voltage in 2 Phase Mode is 0-270 VAC
L1-L2
.
External Magnetics Module available for higher output voltage ranges.
6.
Model 160-AMX - 6.0 kVA, capable of 1 or 2 Phase operation. Single phase output
voltage range is 0-135 VAC
l-n
. Output voltage in 2 Phase Mode is 0-270 VAC
L1-L2
.
External Magnetics Module available for higher output voltage ranges.
7.
Model 305-AMX - 500 VA, capable of 1, 2, or 3 Phase operation. Single and three
phase modes provide 500VA of power with 0-135 VAC
l-n
output voltage range. 2
Phase Mode provides 333VA of power with 0-270 VAC
L1-L2
output voltage. Internal
output transformer available for higher output voltage ranges.