SECTION 2 SPECIFICATIONS
8
2.1.1 INPUT POWER REQUIREMENTS (cont.)
MODEL 120-ASX
INPUT VOLTAGE
The Model 120-ASX accepts one of the following single phase input voltages:
1)
100 VAC ±10%, 47-63 Hz
2)
110 VAC ±10%, 47-63 Hz
3)
120 VAC ±10%, 47-63 Hz
4)
200 VAC ±10%, 47-63 Hz
5)
208 VAC ±10%, 47-63 Hz
6)
220 VAC ±10%, 47-63 Hz
7)
230 VAC ±10%, 47-63 Hz
8)
240 VAC ±10%, 47-63 Hz
INPUT CURRENT
The input current required by the Model 120-ASX at full rated load is stated below.
Recommended input service is also stated.
V
in
INPUT CURRENT
SERVICE RECOMMENDED
1)
100 VAC
22 A
rms
25
A
2)
110 VAC
20 A
rms
25
A
3)
120 VAC
18 A
rms
25
A
4)
200 VAC
10 A
rms
15
A
5)
208 VAC
10 A
rms
15
A
6)
220 VAC
10 A
rms
15
A
7)
230 VAC
9 A
rms
15
A
8)
240 VAC
9 A
rms
15
A
MODEL 140-ASX
INPUT VOLTAGE
The Model 140-ASX accepts one of the following three phase input voltages:
1) 208
VAC
Δ
±10%,
47-63 Hz
2) 220
VAC
Δ
±10%,
47-63 Hz
3) 240
VAC
Δ
±10%,
47-63 Hz
4)
220/380 VAC ±10%,
47-63 Hz
5)
230/400 VAC ±10%,
47-63 Hz
6)
240/416 VAC ±10%,
47-63 Hz
(cost option)
7)
277/480 VAC ±10%,
47-63 Hz
INPUT CURRENT
The input current required by the Model 140-ASX at full rated load is stated below.
Recommended input service is also stated.
V
in
INPUT
CURRENT
SERVICE
RECOMMENDED
1)
208 VAC
Δ
13
A
rms
20
A
2)
220 VAC
Δ
12
A
rms
20
A
3)
240 VAC
Δ
11
A
rms
15
A
4)
220/380 VAC
7 A
rms
10
A
5)
230/400 VAC
7 A
rms
10
A
6)
240/416 VAC
6.5 A
rms
10
A
7)
277/480 VAC
5.5 A
rms
10
A