2.5.1.1 4-Lead Motor
Introduction
For the 4-lead standard systems motor with MS connector, build
and install the cable as follows.
Cable
requirements
Use 16- to 14-gauge stranded wire for the cabling. Obtain cable
with each winding pair (refer to diagram) twisted at about 3 to 4
turns per inch (1 to 1.5 turns per centimeter). Make sure the
cable contains a lead for grounding. As an option, the cable may
be shielded to reduce radiated noise. If a shield is used, connect
as shown for Pacific Scientific cables.
Cabling
diagram
The colors referenced in the diagram follow the Pacific Scientific
stepper motor color code.
Procedure
1. Strip the wires to 0.27 inch (7 mm).
2. Attach the wires to the connector as indicated in the diagram.
Note: Make sure the screws on the PCD connector are tightened
down firmly to the wiring.
1
2
3
4
5
To
Drive
To
Motor
A (Black)
A (Orange)
B (Red)
B (Yellow)
Motor Case
Gnd (Green)
.27 in
.27 in
.27 in
.27 in
.27 in
(7 mm)
(7 mm)
(7 mm)
(7 mm)
(7 mm)
5645 Installation and Hardware Manual
2 - 13
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com