13
SECTION 2
SPECIFICATIONS
2
SPECIFICATIONS
This section states the electrical and mechanical specifications of the ACX Power Source.
Some specifications are controller dependent and are noted as such.
2.1 ELECTRICAL SPECIFICATIONS
2.1.1 INPUT POWER REQUIREMENTS
The following input power forms are accepted by the ACX
INPUT VOLTAGE
The Model ACX accepts any single phase input voltage of 115-240 Vac, 50Hz or 60 Hz Nominal
and is tolerant of transient overvoltages typically present on the AC MAINS power distribution
lines.
INPUT CURRENT
The input current required by the ACX varies by model based on their maximum full rated load.
AC input currents shown below apply to model 118ACX for most common nominal line voltages.
Recommended input service is also stated. Lower power ACX models have proportionally lower
AC input currents. Overload conditions will result in higher input currents that still fall within the
recommended input service. However, at low AC line voltages, the AC input current is
electronically limited at 25Arms. This allows full rated power down to 115V -10% or 103VAC L-N
(Low Line Voltage).
NOTE:
In low voltage operations the max input current is electronically limited to
25A
RMS
maximum
. At least 12AWG input cable wire is recommended.
V
in
INPUT CURRENT
SERVICE RECOMMENDED
103 VAC
25 A
rms
30 A
110 VAC
24 A
rms
30 A
120 VAC
22 A
rms
30 A
200 VAC
13 A
rms
20 A
208 VAC
13 A
rms
20 A
220 VAC
12 A
rms
15 A
230 VAC
12 A
rms
15 A
240 VAC
11 A
rms
15 A
FIGURE 2.1
INPUT CURRENT VS. OUTPUT POWER FOR MODEL 118ACX