background image

IMPORTANT SAFETY INSTRUCTIONS

To ensure the safe operation of this machine, you must read and understand all warnings and instructions in this book.  If you 

do not understand, ask your supervisor. 

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE

WARNING

:  To reduce the risk of fire, electric shock, or injury:

1.  You must be trained to operate this machine.  This machine is to be operated for its intended use only.

2.  Do not operate this machine unless it is completely assembled.

3.  Always use a three-wire electrical system connected to the electrical ground.  For maximum protection against electrical 

shock, use a circuit that is protected by a ground fault circuit interrupter.  Consult your electrical contractor.

4.  To prevent electric shock, always remove the electrical plug from the electrical outlet before doing any repairs or mainte-

nance and when leaving the machine unattended. 

5.  To prevent electric shock, keep the machine surface dry.  Do not subject to rain.  Store the machine in a dry building area.  

Clean the machine with a dry cloth only.

6.  Machines can cause an explosion when near flammable materials and vapors.  Do not use this machine with or near fuels, 

grain dust, solvents, thinners, or other flammable materials.  Do not use flammables to clean this machine.

7.  A qualified or authorized person must do maintenance and repairs.

8.  To prevent damage to the power cord, do not move this machine over the power cord.  Always lift the power cord over 

the machine.  Do not pull or carry cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or 

corners.  Keep cord away from heated surfaces.

9.  Do not use with damaged cord or plug.  If the machine is not working as it should, has been dropped, damaged, left out-

doors, or dropped into water, return it to a service center.

This machine must be grounded.  If it should malfunction or break down, grounding provides a path of least resistance for electric current to 

reduce the risk of electric shock.  This machine is equipped with a cord having an equipment-grounding conductor and grounding plug.  The 

plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING

 - Improper connection of the equipment-grounding 

conductor can result in a risk of electric shock.  Check with a quali-

fied electrician or service person if you are in doubt as to whether 

the outlet is properly grounded.  Do not modify the plug provided 

with the machine.  If it will not fit the outlet, have a proper outlet 

installed by a qualified electrician.
This machine is for use on a nominal 120-volt circuit, and has a 

grounded plug that looks like the plug illustrated in figure A.  A 

temporary adapter that looks like the adapter illustrated in figures 

B and C may be used to connect this plug to a 2-pole receptacle 

as shown in figure B if a properly grounded outlet is not avail-

able.  The temporary adapter should be used only until a properly 

grounded outlet (figure A) can be installed by a qualified electri-

cian.  The green colored rigid ear, lug, or the like extending from 

the adapter must be connected to a permanent ground such as 

a properly grounded outlet box cover.  Whenever the adapter is 

used, it must be held in place by a metal screw.

NOTE: In Canada, the use of a temporary adapter is not permitted 

by the Canadian Electrical Code

EXTENSION CORDS

Use only three-wire 12/3 or larger gauge approved extension 

cords that have three-prong grounding type plugs and three-pole 

receptacles that accept the appliance’s plug.  Replace or repair any 

damaged cords or plugs.

When servicing, refer to authorized person only.  Use only identi-

cal replacement parts.

Grounding Instructions

NOTE:

  Do not use adapters shown in figures B & C in Cana

da

2

Summary of Contents for FM-17DS

Page 1: ...skegon MI 49442 6252 Carefully inspect all components to ensure that there is no concealed freight damage If such damage is discovered file a CONCEALED DAMAGE REPORT immediately with the delivering carrier The contents of this manual are based on the latest product information available at the time of publication Pacific reserves the right to make changes or improvements without notice Thank you f...

Page 2: ... center This machine must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This machine is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local c...

Page 3: ... pad speed or to HIGH for 300 RPM pad speed OPERATION Plug the machine s power cable into a properly grounded outlet see Safety Instructions Next adjust the handle height to a comfortable position Pull out on the Watch Dog Safety Lock button and start the machine by depressing either the left or right switch levers Both hands should be placed on the handle when the machine is in operation The mach...

Page 4: ...4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 19 34 35 36 19 56 40 41 43 44 36 45 52 47 51 50 49 48 47 46 28 29 30 30 31 32 33 FM 17DS FM 20DS FLOOR MACHINES ...

Page 5: ...ut 10 32 Elastic Stop 1 36 980002 Washer 1 4 Lock 6 12 509830 Washer Handle Tube 1 40 502397 Cover Motor Dual Speed 1 13 503320 Flange Strain Relief 1 41 See Page 6 Motor Gear Box Assembly 1 14 505720 Handle Nipple 2 43 481202 Bumper 17 1 15 Use 483921 Handle Assm 1 481203 Bumper 20 1 16 515150 Warning Label 1 44 980004 Washer 1 4 Flat 4 17 501210 Bumper Handle 1 45 962010 Screw 1 4 20 x 1 HH 4 18...

Page 6: ...6 FM 17DS FM 20DS FLOOR MACHINES MOTOR GEAR BOX ASSEMBLY 56 40 ...

Page 7: ...41 Speed Control 230V 1 K 908024 Cord Assembly Motor 1 L 508519 Strain Relief 1 M 505181 Light Brush Indicator 115V 1 505182 Light Brush Indicator 230V 1 N 911115 Switch Rocker 20 Amp 1 O 509823 Washer Felt 1 P 911048 Rectifier Bridge 115V 1 911081 Rectifier Bridge 230V 1 Q 960018 Bolt Motor Thru 2 R 502928 End Bell Motor Top 1 S 500425 Armature Assembly 115V 1 500423 Armature Assembly 230V 1 T 50...

Page 8: ...n of those items To secure repair under this warranty the following procedure should be taken The inoperative machine or warranted parts must be delivered to the authorized dealer with shipping and delivery charges prepaid If unable to locate the Dealer you may contact Pacific at the address listed herein for the location of the nearest Pacific repair center or agent or for other instructions pert...

Reviews: