background image

IMPORTANT SAFETY INSTRUCTIONS

READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS

BEFORE USING THIS APPLIANCE!

WARNING!  To reduce the risk of fire, electric shock, or injury:

1.

Unplug from outlet when not in use and before servicing.

2.

Do not use outdoors.  Protect the machine from rain.

3.

Do not allow to be used as a toy.  Close attention is necessary when used by or near children.

4.

Use only as described in this manual.

5.

Never use this machine to pick up volatile or explosive materials!

6.

Do not use this machine for pick up of dust or dry debris.

7.

Do not use with damaged cord or plug. If appliance should not work as it should, has been dropped or

       damaged, left outdoors, or dropped into water, return it to service center.
8.

Do not pull or carry by cord, use cord as handle, close a door on cord or pull cord around sharp

       edges or corners.  Do not run appliance over cord.  Keep cord away from heated surfaces.
9.    Do not unplug by pulling on cord.  To unplug, grasp the plug, not the cord
10.   Do not handle plug or appliance with wet hands.  Do not immerse.  Keep the machine in a dry building.
11.   Do not put any objects into opening.  Do not use with any opening blocked: keep free of dust, lint,
       hair and anything that may reduce airflow.
12.  Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts.
13.  Turn off all controls before unplugging.
14.  Do not use in areas where flammable or combustible liquids such as gasoline may be present.
15.  Connect to a properly grounded outlet only.

16.  Do not use water that is hotter than 140

°

F (60

°

C).

17.  To prevent damage to the solution system, do not store in freezing temperatures without proper maintenance.

This machine must be grounded.  If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock.  This machine is equipped with a cord having an equip-
ment-grounding conductor and grounding plug.  The plug must be inserted
into an appropriate outlet that is properly installed and grounded in accor-
dance with all local codes and ordinances.

WARNING

 - Improper connection of the equipment-grounding conductor

can result in a risk of electric shock.  Check with a qualified electrician or
service person if you are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the machine - if it will not fit the outlet,
have a proper outlet installed by a qualified electrician.

This machine is for use on a nominal 120-volt circuit, and has a grounded
plug that looks like the plug illustrated in figure A.  A temporary adapter that
looks like the adapter illustrated in figures B and C may be used to connect
this plug to a 2-pole receptacle as shown in figure B if a properly grounded
outlet is not available.  The temporary adapter should be used only until a
properly grounded outlet (figure A) can be installed by a qualified electri-
cian.  The green colored rigid ear, lug, or the like extending from the adapter
must be connected to a permanent ground such as a properly grounded outlet
box cover.  Whenever the adapter is used, it must be held in place by a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code

EXTENSION CORDS

Use only three-wire 14/3 or larger gauge approved extension cords
that have three-prong grounding type plugs and three-pole recep-
tacles that accept the appliance’s plug.  Replace or repair any dam-
aged cords or plugs.

When servicing, refer to authorized person only.  Use only identical replace-
ment parts.

Grounding Instructions

NOTE:

  Do not use adapters shown in figures B & C in Canada

Summary of Contents for TRIUMPH HEAT WAVE

Page 1: ...Pacific Steamex Inc 2259 S Sheridan Muskegon MI 49442 6252 Carefully inspect all components to ensure that there is no concealed freight damage If such damage is discovered filea CONCEALEDDAMAGEREPORT...

Page 2: ...function or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This machine is equipped with a cord having an equip ment grounding condu...

Page 3: ...rain machine of all solution or recovered water Pour undiluted antifreeze into the solution tank and squeeze hand tool lever until anti freeze solution is present in the solution system WARNING Liquid...

Page 4: ...TRIUMPH HEATWAVE FINALASSEMBLY 4 1 4 5 6 7 2 3 10 8 9 28 29 30 31 32 33 27 23 24 25 16 17 13 10 11 12 11 13 15 14 14 18 19 20 21 19 26 13 22 14...

Page 5: ...1 13 S453P Clamp Hose 6 14 214110 Hose 3 8HP 12 4 15 255057 Kit Heater Repair 1 16 251331 Base Assembly Heated Spotter 1 258681 Tank Solution Heated Spotter 1 17 203302 Quick Connect 1 4 Male 1 18 25...

Page 6: ...TRIUMPH HEATWAVE FLOATASSEMBLY 6 1 2 3 4 5...

Page 7: ...OATASSEMBLYPARTS LIST 7 ITEM PART NO DESCRIPTION QTY 1 253301 Ball and Float Assm Complete 1 2 252406 Cap Ball Float Cup 1 3 253801 Grommet Float Shut Off 1 4 251308 Ball Float Shut Off 1 5 253439 Gas...

Page 8: ...embly 400PSI 1 255704 Jet Spray 1 254141 8 Vac Sol Hose Assembly 254122 Hose Vacuum Assembly 8 1 S267P6 Cuff Vac Hose 2 254117 Hose Solution 8 1 203308 Quick Connect Female 1 4 2 217501 Strain Relief...

Page 9: ...TRIUMPHHEATWAVEWIRINGDIAGRAM 9...

Page 10: ...arranty the following procedure should be taken The inoperative machine or warranted parts must be delivered to the authorized dealer with shipping and delivery charges prepaid If unable to locate the...

Reviews: