MACHINE PREPARATION
7. RECOVERY TANK
Open the lid and confirm the following connections are secure:
a. The vacuum cover is securely attached. Align the notches and rotate the cover
clockwise to close. The vacuum hose must also be attached
b. Confirm that the squeegee hose is properly connected
c. Confirm that the drain hose plug, which is located at the front of the machine, is closed
8. SOLUTION WATER
Fill the solution tank with clean water at a temperature not higher than 50°C / 122°F. Add
the proper concentration of liquid detergent by following the manufacturer instructions.
Excess foam in the recovery tank can damage the vacuum motor, so use only the minimum
amount of detergent necessary. Reassemble the cover
WARNING!
Always use low foaming detergent. Adding antifoam liquid into the
recovery tank before cleaning will also help prevent foaming
NEVER USE ACID, BLEACH or AMMONIA
9. BRUSH/PAD DRIVER INSTALLATION
a. Lift the brush base by depressing the foot level at the rear of the machine
b. Place the brushes under the base. Align the brush lugs with the holes in the brush plate.
Insert the brushes into the plate and turn each brush so the lugs are pushed toward their
retaining springs, until locked. The photo shows the directions to rotate the brushes to
lock them into operating position